Basic Info.
Model NO.
ZN23-40.5
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
VDE, ISO9001-2000, CE, CB, CCC
Rated Voltage
40.5kv
Rated Current
1250/1600/2000A
Rated Frequency
50/60Hz
Transport Package
Non-Solid Wooden Case for Export Shipment
Specification
IEC: M2-E2-C2
Trademark
Longxiang Electric
Origin
Baoji, Shaanxi China
HS Code
85389000
Production Capacity
16000sets/Year
Product Description
ZN23-40.5 Truck Type Indoor HV Vacuum Circuit Breaker
General Description
ZW32-12 type outdoor high voltage vacuum circuit breaker is three-phase AC,50(60) Hz outdoor power distribution equipment with
the rated voltage of 12kV. It is mainly used to break and close the load current,and short circuit current in the electric power system.
It fits to be used to protect and control the circuit in substation, mining and industrial enterprises. It also can be used in the frequently
operation places such as the rural power network. The product is accordance with GB1984-2003 standard.
The ZW32-12G VCB -Isolating switch combination consists of Vacuum circuit breaker body and isolating switch.
Applying ambient conditions
1.Ambient temperature:-15~+40ºC.
2.The height above sea level:≤1000m (besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
4.Saturated vapor pressure:the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.Wind pressure should be no more than 700pa(it is equivalent to wind speed of 34m/s).
7.The air filthy should be within III degree.
8.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.
Welcome for enquiry and factory visit!
General Description
ZW32-12 type outdoor high voltage vacuum circuit breaker is three-phase AC,50(60) Hz outdoor power distribution equipment with
the rated voltage of 12kV. It is mainly used to break and close the load current,and short circuit current in the electric power system.
It fits to be used to protect and control the circuit in substation, mining and industrial enterprises. It also can be used in the frequently
operation places such as the rural power network. The product is accordance with GB1984-2003 standard.
The ZW32-12G VCB -Isolating switch combination consists of Vacuum circuit breaker body and isolating switch.
Applying ambient conditions
1.Ambient temperature:-15~+40ºC.
2.The height above sea level:≤1000m (besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
4.Saturated vapor pressure:the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.Wind pressure should be no more than 700pa(it is equivalent to wind speed of 34m/s).
7.The air filthy should be within III degree.
8.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.
Welcome for enquiry and factory visit!