- Overview
- Product Description
- Product Parameters
- Company Profile
Basic Info.
Model NO.
UF2000-B
Application
Industrial Production
Type
Ultrasonic Flow Meter
Measuring Media
Liquid
Measuring Principle
Acoustics
Measurement Object
Closed Pipeline
Certification
CE
Measuring Accuracy
Better Than ±1%
Principle
Transit-Time Measuring Principle
Display
LCD with Backlight
Output
Analog Oct Output Relay Output RS485
Material
Steel, Stainless Steel, Cast Iron, Cement Pipe, Co
Power Supply
AC220V or DC24V
Used for
Tap Water, Industrial Water, and Sewage Treatment
Flow Direction
IP65, IP67, IP68 Customized
Temperature
-30 - 80c
Transport Package
Box
Specification
customized
Trademark
Macsensor
Origin
China
Production Capacity
50000/Months
Product Description
Ultrasonic flow meter uses the time difference principle of ultrasonic wave propagation in the medium to measure the flow rate.It is mainly used to measure liquid, such as ultra-pure liquid, chemical, raw sewage, reclaimed water, cooling water, river water, plant sewage, etc.
Features
Linearity: 0.5%, Repeatability: 0.2%, Accuracy: ±1%
Easy to operate.
Several type transducers for selection, measuring pipe size is from DN15mm to DN6000mm
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
Powerful Recording Function, record the totalizer data of the last 64 days/64 months/5 years.
The wall-mounting flow meter can be applied to a wide range of pipe flow measurements. Applicable
liquids include pure liquids as well as liquid with small quantity of tiny particles.
Examples are:
★ Water (hot water, chilled water, city water, sea water, waste water, etc.);
★ Sewage with small particle content;
★ Chemicals (alcohol, acids, etc.);
★ Plant effluent;
★ Beverage, liquid food;
★ Ultra-pure liquids;
★ Solvents and other liquidsChoosing a Transit Time Ultrasonic Flow Meter offers several compelling advantages for various industrial and commercial applications.
1. High Accuracy
Time Transit Ultrasonic Flow Meters achieve high accuracy by measuring the time difference between ultrasonic signals traveling with and against the flow of the liquid. This method, based on the principle of transit time, ensures precise measurements, typically within ±1% of the reading This high level of accuracy is essential in many industries where precise flow measurement is crucial.
2. Wide Range of Applications
These flow meters can be applied to a diverse range of liquids, including clean water, wastewater, chemicals, oils, and even some non-conductive fluids. Their versatility makes them suitable for industries such as water utilities, chemical processing. The ability to measure a wide variety of liquids without the need for direct contact with the fluid makes them highly desirable.
3. Non-Invasive Measurement
Time Transit Ultrasonic Flow Meters are clamp-on devices that attach to the outside of the pipe, eliminating the need for pipe cutting or insertion. This non-invasive measurement technique minimizes disruption to the flow and avoids the potential for leakage. It also allows for easy installation and maintenance without the need to shut down the process.
4. Long-Term Reliability
With proper installation and maintenance, Time Transit Ultrasonic Flow Meters can provide reliable measurements over an extended period. Their transducers are designed to withstand harsh environments and can operate in a wide range of temperatures and pressures. Additionally, their non-contact nature reduces wear and tear, further enhancing their reliability.
5. Versatile Pipe Compatibility
These flow meters can be used with a variety of pipe materials, including steel, stainless steel, cast iron, copper, PVC, and more. They can also accommodate pipes with different diameters, from small to large, making them suitable for various piping systems.
6. Advanced Features
Macsensor Transit Ultrasonic Flow Meters come equipped with advanced features such as LCD displays, signal outputs (e.g., 4-20mA, pulse, relay), data interfaces (e.g., RS485, MODBUS), and the ability to upgrade software via computer. These features enhance the functionality and usability of the flow meter, allowing for remote monitoring, data logging, and easy integration into existing systems.
7. Cost-Effective
Although the initial investment in a Time Transit Ultrasonic Flow Meter may be higher than some other flow measurement technologies, its long-term reliability, versatility, and ease of maintenance often make it a cost-effective solution. The elimination of downtime and disruption during installation and maintenance, combined with its ability to measure a wide range of liquids, can result in significant savings over the lifetime of the flow meter.
In conclusion, Time Transit Ultrasonic Flow Meters offer a combination of high accuracy, versatility, non-invasive measurement, long-term reliability, and advanced features that make them an attractive choice for a wide range of industrial and commercial applications.
UF2000B | Parameter | |
Host | Principle | Transit- time ultrasonic flow meter |
Accuracy | ±1% | |
Display | 2X20 character LCD with backlight, support Chinese, English and Italy languages | |
Signal Output | 1 way 4~20mA output, electric resistance 0~ 1K, accuracy 0. 1%(optional) | |
1 way OCT pulse output(Pulse width 6~1000ms, default is 200ms) | ||
1 way Relay output | ||
Signal Output | 3 way 4~20mA input, accuracy 0. 1%, acquisition signal such as temperature, press and liquid level | |
Connect the temperature transducer Pt100, can finish the heat/energy measurement | ||
Data Interface | Insulate Rs485 serial interface, upgrade the flow meter software by computer, support the MODBUS | |
Special Cable | Twisted-pair cable, generally, the length under 50 meters ; Select the RS485, transmission distance can over 1000m | |
Pipe Installation Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed |
Pipe Diameter | DN32~6000mm | |
Straight Pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump | |
Work environment | Protection grade | Host:IP67; flow sensor:IP68 |
temperature | Host:-20~60 ; flow sensor:-30~ 160 | |
Humidity | Host: 85%RH; | |
Flow sensor can measure under water, water depth^2m (transducer sealed glue) | ||
Power Supply | DC8~36V or AC85~264V | |
Power Consumption | 1.5W | |
Frequency | 0.5MHz | |
Repeatability | 0.2% |