Water Oil Liquid Tank Level Indicator Magnetic Glass Float Level Indicator

Customization: Available
Principle: Magnetic Sensors
Range: 0-10m

Products Details

Basic Info.

Model NO.
UHC
Warranty
1 Year
Certification
CE, RoHS
Material
CS, Ss304, 316L, Steel Lined with PP, PTFE
Process Temperature
-40 to +450 Degree C
Mounting
Side, Top, Side-Top Flange or Thread
Level Switch
High Level, High High Level, Low Level, Low Low
Swtich Type
COM, No., Nc. Control Switch
Transmitter
4~20mA Output Signal
Float Working Density
>0.5g/cm3
Measure Range
<10m
Norminal Pressure
1.0MPa, 1.6MPa, 2.5MPa, 4MPa, 6.3MPa, 10MPa, 16MPa
Working Temperature
-40~450 C
Valves
with Drain Valve, Vent Valve
Transport Package
Wooden Case or Carton
Specification
0~10m
Trademark
U-ideal
Origin
Tianjin, China
HS Code
90261000
Production Capacity
5000

Product Description

magnetic level gauges 
  1. Easy to install, no extra piping required in most applications
  2. Magnetic level gauge Visual level indication up to 30m, sections made suit for delivery. Magnetostrictive level indicator can reach 30m measure range with cable insertion.
  3. Ideal for high-temperature, high-pressure and corrosive applications.
  4. Magnetostrictive and radar transmitter options for non-invasive and/or redundant level control.
  5. Available with HART, 4~20mA, and level switches.
Float Cage Material SS304, SS316, PTFE, PP, PVC, PVDF
Max. Centre to Centre Distance 6000 mm, greater lengths on request
Connecting Flanges According to DIN or ANSI B16.5
Temperature of Liquid 450ºC (Max.) for SS, 80ºC (Max.) for PVDF
60ºC (Max.) for PVC, 50ºC (Max.) for PP
Specific Gravity Min. 0.45
Scale Graduated in cm, Aluminium or SS304
Measuring Accuracy +/- 5 mm

Floats UHC Floats are specifically calibrated to match the conditions of the vessel. The density, operating pressure and temperature are taken into account, ensuring that the inferred level is accurate and repeatable.
Floats material: SUS304, SUS316, PTFE, PP, and Titanium.
Anticorrosive material: such as stainless steel SUS 304 or SUS316L, Teflon PTFE, polypropylene (PP), FRP and advanced tech. application such as X-ray detection, cold-rolling broaching weld, all ensure that the product can be adapted to any demand at site. Additional blow off valve can be added onto the bottom sealing type of the tube when necessary.
 
Your application is unique, All U-ideal instruments are custom-made based on your requirements.
Water Oil Liquid Tank Level Indicator Magnetic Glass Float Level Indicator

U-ideal mounting styles
No matter what your application, we can design and manufacture a magnetic level indicator to fit. Above are our standard mounting styles, but if none of these meet your needs we will come up with the best solution based on your requirements.
NOTE: Style "4" is for through process piping only. Other connections shown are examples of typical process connections and need to be specified.

Typical pictures of magnetic level indicators
Water Oil Liquid Tank Level Indicator Magnetic Glass Float Level Indicator
Model Selection Table
Basic selection of magnetic level indicator please refer to the following steps:
UHC- C Side mounted;
  D Top mounted
O Other
Signal Y  Standard transmitter 4~20mA current signal (Resolution: 20mm/10mm/5mm);
Y3 Magneticostrictive transmitter 4~20mA
H Hart;
A Switch and number;
L transmitter with LCD
  No signal output
Indicator type O Ordinary pannel
S Sealed bargraph
L Red/Green flaps with LED lamp
Structure S Steam tracing
E Electric heating
F Defrost
Valve D Drain valve or drain plug
DV Drain valve and Vent valve or plug
N No valve
Working temperature A Ambient temperature (0~40ºC)
M -20~200ºC
H High temperature (<400ºC)
L If easy frozen
Material SS304 0Cr18Ni9
SS316L 022Cr17Ni12Mo2
SS321 0Cr18Ni10Ti
PP PP (Polypropylene),PVC,PVDF
PTFE stainless steel lined with PTFE
Explosion-proof S Safety environment
E Explostion-proof ExdII BT4
I intrinsic safety ExibII CT4
Measure range   Unit: mm
Fluid density  g/cm3
working pressure Unit: MPa
Flange size, rate and standard ANSI DIN JIS
Example: UHC-C-YA-O-D-M-SS304-S-500-0.8-1-DIN DN25 PN16

Remark: Manufactured customized is available for this product.
 
Can make to Sections if gauge is longer than 3m to make suitable for delivery.


Special working conditions magnetic level gauge
UHC - V side-top mounted high viscous liquid Float level gauge
UHC - V side-top mounted high viscous liquid type Float level gauge is suitable for the petrochemical tank liquid level measurement system, and especially suitable for heavy oil, tar, crude oil, resin of high viscosity medium liquid level detection.
 Water Oil Liquid Tank Level Indicator Magnetic Glass Float Level Indicator
 
  1. C-C: 500 ~ 10000 mm, long gauge can be section made.
  2. Process connection: size DN6 ~ DN200, flange standards (GB, JB/T, HGJ, ANSI, DIN, etc).
  3. Lead tube material: 304SS; 316SS; 316L
  4. Float material: 304SS; 316L, Titanium
  5. Working pressure: 0 ~ 1.6 MPa
  6. Working temperature: - 20 ~ 200 ºC
  7. Accuracy: + / - 10 mm
  8. Medium density: 0.65 ~ 2.0 g/cm3
  9. Medium viscosity: 1.5 Pa s. or less
 
UHC-V Top-side mounted high viscosity fluid type float level gauge
  L drain valve valve
  B SS304 or stainless steel 1Cr18Ni9Ti wet material
L 316SS or 316L
  150 DN150 or 6" Connection
200 DN200 or 8"
  A Flange nominal pressure 1.0MPa PN
B Flange nominal pressure 1.6MPa
  1 -20~80ºC Working temperature
2 -20~130ºC
3 -20~200ºC
  B cam magnetic drive switch switches
C reed switch
  number of switches
R1 standard transmitter 4~20mA transmitter
R2 magnetostrictive transmitter 4~20mA
R3 magnetostrictive transmitter 4~20mA, with Hart
  O standard ex-proof
D flame-proof  ExdiiBT4
E intrinsic safety ExibiiCT4
  height of install
  width of install
  measure range
  fluid density
working pressure


Top mounted vaporizing fluid float level gauge
UHC -T Top mounted vaporizing fluid special using magnetic float level gauge is suitable for liquid measurement which is easy vaporization in pressure vessels, especially for buried tank of liquid level measurement such as liquefied petroleum gas, methane. This model level gauge adopts of a set of three pure titanium floats and unique guide rail structure, with stable and reliable product performance, strong practicability, now is widely used in LPG stations.
Water Oil Liquid Tank Level Indicator Magnetic Glass Float Level Indicator

 
  1. Measuring range: 300 ~ 3000 mm. 
  2. The process connection: flange size is 6 ~ DN200, flange standards (GB, JB/T, HGJ, ANSI, DIN, etc) please declare when ordering.
  3. Lead tube material: stainless steel 1Cr18Ni9Ti; 304SS; 316SS; 316L
  4. Float material: Titanium
  5. Working pressure: -0.1 ~ 4 MPa
  6. Working temperature: - 80 ~ 80 ºC
  7. Accuracy: + / - 10 mm
  8. Medium density: 0.4 ~1.2 g/cm3
  9. Medium viscosity: 0.4 Pa s.
 
Model Selection:
UHC-T Top mounted vaporizing fluid special using float level gauge
  B SS304 or stainless steel 1Cr18Ni9Ti wet material
L 316SS or 316L
  150 DN150 or 6" process connection
200 DN200 or 8"
  A Flange nominal pressure 1.0MPa nominal pressure
B Flange nominal pressure 1.6MPa
  1 -20~80ºC Working temperature
5 -80~80ºC
  B cam magnetic drive switch switches
C reed switch
  number of switches
R1 standard transmitter 4~20mA transmitter
R2 magnetostrictive transmitter 4~20mA
R3 magnetostrictive transmitter 4~20mA, with Hart
  O standard ex-proof
D flame-proof  ExdiiBT4
E intrinsic safety ExibiiCT4
  J3 Vacuum jacketed
  height of install
measure range
fluid density
working pressure

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours