- Overview
- Product Description
- Our Advantages
- Company Profile
- FAQ
Basic Info.
Product Description
Order No.: CTH2 216-1BD33-0X24
Specification: CPU H226M:12KB program memory/8KB data memory,220VAC power supply,14DI*10DO,relay output,2A,2*PPI/FPORT,1*Ethernet port(do not support CAN expansion board and SM253)
CTH200 series PLC is a kind of automatic controller product introduced by COTRUST, which aiming at the rapidly developing OEM market in China. Fuled by the abundant experience of COTRUST engineers and the quick response to marketing demand of industry 4.0, it owns traits from rich-model to Ethernet to excellent performance. CTH200 series PLC will not just offering OEM clients with cost-effective solution of micro automation, but speed the development process of industry 4.0 in China. CTH200 is a general terms for all CPU products(nine types in all), including CPU H224, CPU H226L, CPU H224X, CPU H226XL and CPU H228XL(the CPU H228XL is just relay-output while others support both relay and transistor ). Supporting for variety of modules, such as digital I/O modules, analog I/O modules, temperature sampling modules and so on gives you flexible choice in front of industrial automation problem. CTH200 PLC communicates with computer via Ethernet port or RS485 port, and programs on MagicWorks PLC (version V2.08 or above) or MicroWin(not suit for Ethernet port). CTH200 system can be made up by one single CPU as well as one CPU with up to 7 variousoptional expansion modules. |
Performance Parameters
Physical Features CTH2 216-1BD33-0X24 | |
Dimension(W×H×D) | 137×80×62mm |
Power dissipation | 7W |
Memory Features | |
Program memory | 8KB+4KB |
Data memory | 8KB |
General Features | |
Timers total 1ms 10ms 100ms | 256 4 16 236 |
Counters total | 256 |
Internal memory bits | 256 |
Stored permanently on power down | Data permanent stored |
Sequential control relay (S) | 256 |
Time Interrupts | 2 with 1ms resolution |
Edge Interrupts | 4 rising edges and/ or 4 falling edges |
Analog adjustment | Non |
Boolean execution speed | 0.22µs |
Float execution speed | 12µs |
Clock | embedded ,precision ±120s/m |
BD expansion board interface number | 1 |
System indicator | 3,STOP,RUN,SF |
RUN/STOP dial code | Yes,2 |
Programming card | Support |
Memory card | Non Support |
Rated input voltage | 24VDC |
Power supply Native and extended bus+5V +24V | 660mA 200mA |
Integrated Communication Function | |
Communication Interface | 2 communication ports ,PORT0:PPI/Free port,RS485;FPORT0:PPI/Free port,RS485 |
PPI baud rates(baud) | 9.6k,19.2k and 187.5k |
Freeport baud rates(baud) | 1.2k ~ 115.2k |
Maximum cable length Isolated repeater applied Isolated repeater unapplied | When it is 1000 m, baud rate is 187.5k; when it is 1200 m, 38.4k. 50m |
Maximum number of stations | 32 stations per segment,126 stations per network |
Maximum number of masters | 32 |
Physical interface | 2 RS485 port |
Isolation | Non |
Ethernet Function | |
Communication port | 1 Ethernet port |
Communication standard | IEEE802.3 standard |
Communication speed | 10Mbps and 100Mbps self-adaption |
Adaptive cross connection | Non support |
Interface to industrial Ethernet(10/100Mbps) | RJ45 port |
Protocol type | UDP/TCP protocol Support MICO Ethernet programming, support Ethernet communication between PLC. |
Collocation method | Support the upper computer through the Ethernet port search PLC, support the mouth download system configuration. |
Max Connections | Each PLC supports up to 8 UDP connections and up to 4 TCP connections. |
The maximum number of IT connections | 8 UDP_PPI connections, with 4 master stations and 4 slave stations. 4 ModBus_TCP connections, 2 master stations and 2 slave stations. |
User data number | Up to 200 bytes are used for TCP/IP transmission. Up to 240 bytes are used for ModBus_ TCP transport. |
Port | local:1~65535 remote server:8888 |
Boot time or restart time after reset | 3 seconds |
Indicator lamp | Green RMC indicator: on: remote control in effect, off: remote control out Green Ethernet indicator: on: connection, flicker: transmission; out: not connected |
Maximum cable length | 100m |
Isolation | Communication port isolation |
I/O Features | |
Number of integrated digital inputs | 14 |
Input type | Sink/Source |
Number of integrated digital outputs | 10 |
Output type | Solid-MOSFET |
Digital I/O mapping domain | 128DI/1280DQ |
Analog I/O mapping domain | 32AI/32AQ |
Maximum number of expandable I/O module | 7 |
Maximum digital I/O configuration | IO:256(128DI/128DO) |
Maximum analog I/O configuration | 64(32AI/32AQ) |
Pulse catch inputs | 14 |
High-speed counters Total Uniphase counters Bi-phase counters | 4 4×50KHz 1×30KHz |
Digital Input Features | |
Number of integrated digital input | 14 |
Input type | Sink/ Source |
Rated voltage | 24V DC |
Input voltage range | 20.4-28.8V DC |
Surge voltage | 35V DC,continuously 0.5s |
Logical 1 Signal (minimum) Logical 0 Signal (Maximum) | 15 VDC,2.5mA 5 VDC,1mA |
Allowable leakage current | 1mA |
Input filter | 3.4ms and 6.4ms |
Isolation(field side to logical circuit) | 500V AC,1min |
Simultaneous input | 14 |
Maximum cable length Shielded Unshielded | 500 M(standard input) 50 M(high-speed counters input) 300 M(standard input) |
Digital Output Features | |
Number of integrated digital output | 10 |
Output type | Dry contact |
Rated voltage | DC:24V or 110V/220VAC |
Output voltage range | 5~30VDC:5~250VAC |
Logical 1 Signal (minimum) | - |
Logical 0 Signal (Maximum) | - |
Rated current per point | 2A |
Rated current for each common point | 8A |
Leakage current (maximum) | |
Surge current(Maximum) | 7A |
Lamp load (maximum) | 30W DC/200W AC |
On resistance (contact) | 0.2Ω |
Isolation(field side to logical circuit) | - |
Delay | Off to on:- on to off:- |
Contact life at rated load | 100000 times on and off |
Simultaneous input | All output point |
Parallel output | Non |
Maximum cable length Shielded Unshielded | 500m 150m |
RS485 communication port definition
Connector | PIN | PORT0(RS485) | FPORT0(RS485) |
| 1 | Shell Grounded | Shell Grounded |
2 | logically | logically | |
3 | RS485+signal B | RS485+signal B | |
4 | Send the application RTS | Send the application RTS | |
5 | logically | logically | |
6 | +5V, series connection 100 Ω resistance | +5V, series connection 100 Ω resistance | |
7 | +24V | +24V | |
8 | RS485-signal A | RS485-signal A | |
9 | NC | NC | |
shell | Shell Grounded | Shell Grounded |
Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.
Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.
Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.