Basic Info.

Model NO.
ZZYS30
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Gas, Steam, Liquid
Size
DN15-DN300
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Gas, Steam, Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Repeatability
0.3%
Medium Temperature
-40-240
Ambient Temperature
-40-85
Medium Pressure
≤100 Bar, More Pressure Need Be Customized
Material
Sensor: 316L, Hc276
Output
Two Wire 4~20mA
Ex-Proof Class
Exd II CT6 CE19.1438 Ex ( Ia ) II CT6
Housing Protection Class
IP67
Mounting Type
Integral Mounting, Split Mounting
Transport Package
Carton
Specification
20CM*10CM*30CM
Trademark
CAMCT
Origin
China
Production Capacity
50, 000.00 Sets/Year

Product Description

Product Description

Product Overview

The ZZYS30 vortex flowmeter is an advanced velocity flow instrument designed for a plethora of applications.
This versatile device is perfect for measuring, monitoring, and managing the flow of liquids, steam, and most gases.
Engineered with an innovative structure, it boasts exceptional resistance to mechanical vibrations, impacts, and contamination.
Featuring no moving parts, it guarantees no wear and tear, eliminating the need for mechanical maintenance. Experience low pressure loss, stable performance, and unparalleled accuracy.
Installation is a breeze, with the flexibility to match the sensor and signal converter as needed.


Product features:

Broad application range, making it ideal for steam, gas, and liquid flow measurement.
Outstanding vibration resistance with zero drift at zero point, effectively neutralizing external vibration influences.
The ZZY30 also offers integrated temperature and pressure options, which can significantly save on installation costs.
Provides flexible output options including (0-5) kHz frequency output, (4-20) mA output, or HART/Modbus protocol communication.
Supports parameter setting through Bluetooth communication. It is wear-resistant, dirt-resistant, requires no mechanical maintenance, has a long service life, and is explosion-proof for enhanced safety.

Detailed Photos

Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Product Parameters

Technical Index

Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: 25mm, 32mm, 50mm, 80mm, 100mm.
Flange Connection Type: Caliber Selection of 100mm, 150mm, 200mm
Flow Measurement Range: Normal measurement flow velocity range with a Reynolds number of 1.5×104~4×106; gas velocity 5~50m/s; liquid velocity 0.5~7m/s.
Normal Measurement Flow Range: Liquid,
Gas Flow Measurement Range: Please refer to Table 2.
Steam Flow Range: Please refer to Table 3.
Measurement Accuracy: Class 1.0, Class 1.5
Measured Medium Temperature:
Room Temperature -25ºC~100ºC, High Temperature -25ºC~150ºC, -25ºC~250ºC. Output Signal: Pulse voltage output signal, High level 8~10V, Low level 0.7~1.3V. Pulse duty cycle is approximately 50%, transmission distance up to 100m.
Pulse Current Remote Transmission Signal: 4-20 mA, transmission distance up to 1000m. Instrument Use Environment: Temperature -25ºC~+55ºC, Humidity 5~90% RH at 50ºC. Material: Stainless Steel, Aluminum Alloy.
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level: IP65.

Technical parameters
Medium Steam, Gas, Liquid
Measuring range See flow1-3
Caliber DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300
Medium pressure 100 bar, more pressure need be customized
Medium temperature -40°C~+240°C
Ambient temperature Ordinary type: -40°C~+85°C
Ex-proof type: -40°C~+60°C
Accuracy Liquid, Re20000 is ±1.0%, gas and steam, ±1.5%
Repeatability ±0.3%
Material Measuring pipe:304,316L, HC276
Sensor: 316L, HC276
Converter shell: casting aluminum
Instrument caliber Flange connection: DN15-DN300
Clamping connection: DN15-DN100
Flange standard DIN, ANSI, HG20592 (Can be customized)
Pressure loss
Gasandliquid

saturated steam
ΔP=Cqv²Px          ΔP: pressure loss(pa)
                        qv: volume flow
                        qm: mass flow
ΔP=Cqm²Px                    PX: density
                        C: constent
Display Two-line LCD display, four button operation
Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display
Power supply Ordinary type: (14~36) VDC
Ex-proof type: (14~30) VDC
Battery power supply
Loading No-ex-proof: RB=(UB-14DVC)/22MA1200Ω
Ex-proof: RB=(UB-14DVC)/22MA≤600Ω
Output Two wire 4~20mA
Ex-proof class Exd II CT6 CE19.1438 Ex ( ia ) II CT6
Cable interface 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread)
Housing protection class IP67
Connection type Flange (DN15-DN300), Clamping (DN15-DN100)
Mounting type Integral mounting, split mounting (special shielded cable connect the pipe and indicator)

Measuring Range:
Gas
Air: t=20°C    p=1.013bar abs =1.7210-4 mpa.s  Q: flow (sheet 1)
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 6.79 32.56
DN25 24 10.20 113.94
DN40 38 25.3 326.63
DN50 50 43.89 565.49
DN80 74 96.14 1238.64
DN100 97 165.14 2128.27
DN150 146 374.23 4821.57
DN200 193 702.95 9056.8
DN250 253 1123.7 14478
DN300 305 1632.1 21028

Liquid
Water: t=20°C        p=1.013bar abs       10cp                 Q: flow
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 0.45 5
DN25 24 0.81 11.40
DN40 38 2.04 28.57
DN50 50 3.53 49.47
DN80 74 7.74 108.37
DN100 97 13.30 186.21
DN150 146 30.13 421.86
DN200 193 52.66 792.42
DN250 253 90.5 1266.8
DN300 305 113.41 1839.8

Saturated steam

Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=1bar G P=3.5bar G P=5.2bar G P=7 bar G
ρ=1.13kg/m3 ρ=2.43kg/m3 ρ=3.28kg/m3 ρ=4.17kg/m3
t=120.6°C t=148.2°C t=160.4°C t=170.6°C
min max min max min max min max
DN15 16 5.87 36.97 7.68 79 8.93 106.68 10.06 135.69
DN25 24 11.82 129.39 17.26 276.4 20.09 373.53 22.66 474.82
DN40 38 29.64 370.71 43.33 792.33 50.63 1070.2 56.8 1361.2
DN50 50 51.31 641.82 75.02 1371.8 87.19 1852.8 98.33 2356.6
DN80 74 112.41 1405.8 164.33 3004.7 191 4058.4 215.39 5161.8
DN100 97 193.14 2415.5 282.36 5162.7 328.16 6973.3 370.09 8869.2
DN150 146 437.56 5472.4 639.69 11696 743.45 15798 838.44 20093
DN200 193 821.91 10279 1201.6 21970 1396.5 29675 1574.9 37743
DN250 253 1313.9 16433 1920.9 35122 2232.5 47439 2517.7 60337
DN300 305 1908.3 23866 2789.8 51010 3242.4 68899 3656.6 87630


Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=10.5 bar G P=14 bar G P=17.5 bar G P=20 bar G
ρ=5.89kg/m3 ρ=7.6kg/m3 ρ=9.32kg/m3 ρ=10.54kg/m3
t=186.2°C t=198.5°C t=208.5°C t=215.6°C
min max min max min max min max
DN15 16 12.78 191.71 16.51 247.55 20.23 303.36 22.89 343.32
DN25 24 26.93 670.88 30.6 857.88 33.87 955.48 36.04 1201.41
DN40 38 67.51 1878.2 76.72 2150.7 84.93 2395.3 90.35 2557.7
DN50 50 116.89 3251.7 132.82 3723.4 147.03 4147 156.42 4428.1
DN80 74 256.03 7122.4 290.93 8155.8 322.06 9083.7 342.62 9699.3
DN100 97 439.91 12238 499.9 14013 553.38 15608 588.69 16666
DN150 146 996.62 27725 1132.5 31747 1253.7 35359 1333.7 37756
DN200 193 1872.1 52079 2127.3 59634 2354.9 66419 2505.2 70921
DN250 253 2992.7 83254 3400.71 95333 3764.6 106180 4004.9 113380
DN300 305 4346.5 120920 4939.1 138460 5467.5 154210 5816.5 164660

Selection list
model Explanation
ZZY30              
Connection F             Flange connection
W Flange clamping
Temperature
Resistance Class
T1 Match with 250°c probe
T2 Match with 350°c probe







Nominal diameter
015 DN15
020 DN20
025 DN25
032 DN32
040 DN40
050 DN50
065 DN65
080 DN80
100 DN100
125 DN125
150 DN150
200 DN200
250 DN250
300 DN300

Structure
Z Integrated T and P compensation
F Regular model
S Split
Material R1 304
RL 316L



Instrument model
N 24V power supply Output 3 wire pulse
V1 24V power, on-site display, 4-20mA, RS485, Impulse output
V1

B
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output
Pressure Class N Normal
H High pressure

Certifications

Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features

PACKING & SHIPPING

We will deliver your order product at the earliest date as per your requirement, ensuring timely and efficient service.
Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Installation Instructions

Installation Requirements

Piping condition
The installation of the vortex flowmeter necessitates a certain straight pipe section both before and after the sensor. The common scenarios are as follows (D represents the diameter of the pipe):

Piping condition upstream Downstream
Concentric shrinkage
pipe full open gate valve
15D 5D
∠90° square elbow 20D 5D
Same plane 2∠90°elbow 25D 5D
Semi-open gate valve regulating valve 50D 5D
Different plane 2∠90°elbow 40D 5D
With rectifier tube bundle 12D 5D

1.
The sensor should be mounted on a horizontal, vertical, or inclined pipe (with liquid flowing from bottom to top). The pipe should have the same diameter as the sensor. Ensure a straight pipe length of 15-20D upstream and 5-10D downstream to meet the installation criteria.
2.
The pipe adjacent to the liquid sensor should be completely filled with the liquid being measured.
3.
Avoid installing the sensor on pipes that experience strong mechanical vibrations.
4.
The inner diameter of the straight pipe section should match the sensor's diameter as closely as possible. If it is not feasible, use a pipe with a slightly larger diameter, ensuring an error of ≤3% and not exceeding 5mm. The sensor should not be placed in areas with strong electromagnetic interference, restricted space, or where maintenance is inconvenient. Installation requirements.
5.
Horizontal pipeline installation is the most prevalent for flow sensors. When measuring gas flow with minor liquid content, the sensor should be installed at a higher pipeline point. For liquid flow measurements with minor gas content, the sensor should be placed at a lower pipeline point.
6.
Vertical pipeline sensor installation: For gas flow measurements, the sensor can be mounted on a vertical pipe without flow direction constraints. If the gas contains minor liquid content, the flow should be from bottom to top. For liquid flow, the flow should also be from bottom to top to avoid excessive probe weight.
7.
Side installation on horizontal pipelines: Sensors can be side-mounted irrespective of the fluid type, especially for superheated steam, saturated steam, and low-temperature liquids. Side mounting is preferred when feasible to minimize temperature effects on the amplifier.
8.
Inverted sensor installation on horizontal pipelines is generally inadvisable. It is unsuitable for measuring general gases or superheated steam but can be used for saturated steam and high-temperature liquids. It is also suitable for pipelines requiring frequent cleaning.
9.
When installing sensors on pipelines with insulation layers, ensure that the insulation does not exceed one-third of the bracket height, especially when measuring high-temperature steam.
10.
Selecting pressure and temperature measurement points: Depending on the requirements, the pressure measurement point should be located 3-5D downstream of the sensor, and the temperature measurement point should be 6-8D downstream.

Company Profile

Shandong zhongziyi intelligent technology Co.,
Ltd located in Zibo science and technology industrial park.
It takes an area of more than 18,000.00 square meters.
We have high standard and modern manufacturing factory and
committed to
the R&D,
manufacture,
sales and service of pressure and temperature instrument.
We are the standing director unit of national pressure gauge Industry Association and we have obtained ISO9001 quality management system certification and we are the high-tech enterprise in Shandong Province.
we are the supper close partner of Rosemount in China. Our technology closed keep following with Rosemount.
Our factory deeply engaged in instrument R&D and production for almost 60 years,
and we have a very good technology accumulation and customer service experiments.
The products widely using in Petroleum, Chemical industry, Papermaking,
Metallurgy,
Medicine,
Food,
Power and machinery etc. The sales cover the whole country and abroad and won trust and favorable comment from the masses of users deeply.
The company's core goal is "quality first, customer first".
We give hearty welcome to the customers come to our factory to visit and discuss cooperation business.

COMPANY AND FACTORY PICTURE:

Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Our Advantages

Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Features:
  1. The structure is ingeniously simple yet incredibly robust, boasting no moving parts. This design ensures exceptional reliability and fosters long-term operational dependability.Operation is highly dependable.
  1. Installation is a breeze, and maintenance is remarkably convenient.
  1. The detection sensor remains isolated from the measured medium, guaranteeing stable performance and an extended lifespan.
  1. The output is a pulse signal directly proportional to the flow rate, ensuring no zero drift and maintaining high accuracy.
  1. Wide measurement range,range down up to 1:50.
  1. Low pressure loss translates to reduced operating costs and significant energy-saving benefits. Within a specific range of Reynolds numbers, the output signal frequency remains unaffected by variations in the physical properties and composition of the fluid. The meter coefficient's constancy with the shape and size of the vortex shedding body eliminates the need for compensation when measuring fluid volume flow. Typically,recalibration of the meter coefficient is unnecessary even after component changes.


Team Building

We believe in the power of teamwork and trust that the best team always triumphs!

Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
Exhibition Pictures

We are proactively seeking international cooperation through global exhibitions.

Low Pressure Loss Gas Vortex Flowmeter with High Accuracy Features
FAQ

1, What kind of product do you supply?

O
ur product
includes
pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow
meter.

2,What is your product and technology advantages?

Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in
China.
our technology closely
keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

O
ur factory located in Zibo, Shandong province, China, which is top
three
instrument production area.
A
nd take an area of more than 18000 square meters.

4, Can we visit your factory?

Y
ou are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

O
ur product warranty is 12 months from the shipping date, but we provide
lifetime
maintenance.

6, What are your payment terms?

Now
, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union,
PayPal
and trade assurance online payment.

7, What kind of certification do you have?

W
e have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate
a
nd
several
invention patents.

8, How long is your delivery date?

F
or peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

Our products quality enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

Y
ou can send inquiry through our email or cellphone as below:

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours