Input Module of Programmable Logic Controller (PLC) in Alarm System

Customization: Available
Type: Sensor
Usage: Alarm

Products Details

Basic Info.

Model NO.
M-6006
Temperature
Zero Ten Degree to 50 Degree
Power
15-28V
Read Type
Electronic Code
Transport Package
Carton
Specification
56*56*22mm
Trademark
module
Origin
China
HS Code
8531100000
Production Capacity
500000/Month

Product Description

Instruction manual of M-6006 input module

A. Features

1.Installed directly in the embedded box
2.Built-in product ID code
3.Using hardware and software filtering technology to improve the module's anti-jamming capability
4.Linkage,  2 bus type,nonpolarity

B. Specifications

Working voltage linkage 15-28V Impulse voltage
Working current Standby current ≤0.55mA
action current ≤5.5mA
Type Addressable, 2 wire(nonpolarity)
Encoding Electronic code
Module's Indication status Normal monitoring status The green inspection lamp flashes periodically
action state red action light keep lit, green inspection lights keep lit
Operating environment Temperature-10ºC~50ºC Relative humidity≤95%RH,No condensation
 Dimensions 56mm×56mm×21.5mm(transparent cover not included)
Color beige
Weight about 53g(transparent cover included)
Executive standard GB 16806-2006
 

C. Structural features

1.Module's Dimensions and installation dimensions shown in Figure 1

Figure 1 M-6006 Dimensions and installation dimensionsInput Module of Programmable Logic Controller (PLC) in Alarm System
 

D. Installation

WARNING: Before installing the device, the power must be switched off.
  1. The module can be installed in either a exposed way or a concealed installation. As for concealed installation, the module can be installed in the 86H50 standard embedded box, and then installed on the cover just like Figure 2 shows; for exposed way, the module installed in the terminal box which shown in Figure 3.

      
Figure 2 concealed wire diagram                 Figure 3 exposed wire diagramInput Module of Programmable Logic Controller (PLC) in Alarm System


2. wiring method shows in Figure 4Input Module of Programmable Logic Controller (PLC) in Alarm System


Figure 4: M-6006 wiring diagram
3. Wire requirements: Wire (bus) should be RVS-2 * 1.0 mm2 or 1.5 mm2; RVS-2*1.0 mm2 or 1.5 mm2 for signal input wire.


E. Use and operation
Encoding operation: you can use our company's hand-held encoder M-6006 to live coding. When encoding, connect the two clips of the encoder to the two terminals of the linkage, open the handheld encoder power, enter the address code to be written (address code range must be: 1-242, the address code for the same loop is unique). Press the "write code" button, if encoding is successful, the encoder will display the address number after sending the address code. If failed, the encoder will display "FAL" after sending the address code.
For details on the steps and methods of encoding, refer to the "M-6006 Handheld Encoder User's Manual".
.

F. Note

1. The alarm function test of smoke detector should be performed every six months.
2. When the controller detects the cleaning forecast, please send the number of smoke detectors back to the company for cleaning, in order to avoid false or false positives, resulting in unnecessary losses.


Input Module of Programmable Logic Controller (PLC) in Alarm System
Input Module of Programmable Logic Controller (PLC) in Alarm System
Input Module of Programmable Logic Controller (PLC) in Alarm System
Input Module of Programmable Logic Controller (PLC) in Alarm System
Input Module of Programmable Logic Controller (PLC) in Alarm System
Input Module of Programmable Logic Controller (PLC) in Alarm System
Input Module of Programmable Logic Controller (PLC) in Alarm System
Input Module of Programmable Logic Controller (PLC) in Alarm System
Input Module of Programmable Logic Controller (PLC) in Alarm System


 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours