Basic Info.
Model NO.
XYT909
Certification
CE
Customized
Customized
Transport Package
Carton
Specification
0.5kg
Trademark
XYT Meter
Origin
China
HS Code
9026201090
Production Capacity
50000 Piece /Years
Product Description
Product Description
Radar Level Meter
Radar level meter antenna by narrow microwave pulse, the pulse propagation in space at the speed of light, meet the measured medium surface, the part of the energy to be reflected back, by the same antenna. Emission pulses and the time interval of the received pulse and the antenna to the measured medium surface is proportional to the distance. Due to the electromagnetic wave propagation and very high speed, pulse and receiving pulse time interval is very small (nanosecond) it is difficult to confirm, xYT90X series of 26G radar level meter adopts a special demodulation technology, can accurately identify the transmitted pulse and pulse interval, thus further calculate the antenna to the measured medium surface distance.
Application: Rivers, Lakes, Shoal
Measuring Range: 70 meters
Process Connection: Thread G1½ A″ /Frame /Flange
Temperature: -40ºC ~ 100ºC
Process Pressure: Normal pressure
Precision: ± 10mm
Frequency Range: 26GHz
Protection Grade: IP67 / IP65
Power Supply: (6 - 24V) DC / Four-wire
24V DC / Two wire
The Signal output: RS485 / Modbus ( 6~24V DC)
4~20mA / Hart Two wire ( 24V DC)
The Scene Display: Optional
Outer Covering: Aluminum / Plastic / Single chamber
Application: Rivers, Lakes, Shoal
Measuring Range: 30 meters
Process Connection: Thread G1½ A″ /Frame /Flange
Temperature: -40ºC ~ 100ºC
Process Pressure: Normal pressure
Precision: ± 3mm
Frequency Range: 26GHz
Protection Grade: IP67 / IP65
Power Supply: (6 - 24V) DC / Four-wire
24V DC / Two wire
The Signal output: RS485 / Modbus ( 6~24V DC)
4~20mA / Hart Two wire ( 24V DC)
The Scene Display: Optional
Outer Covering: Aluminum / Plastic /Single chamber
Technical Parameters
The outer shell
The seal between the shell and the shell cover Silicone rubber
Casing window Polycarbonate
The ground terminal Stainless steel
The power supply voltage
Four wire system (6~24) V DC / RS485 Modbus / Power dissipation 90mW
Two wire system DC 24V / 4~20mA / Power dissipation 0.75W
Allowable ripple
- <100Hz Uss<lV
- (100~100K) Hz Uss<l0mV
The cable parameters
Cable entrance / plug 1 M20xl.5 cable entrance
1 blind plug
Terminal Conductor cross section 1.0mm²
Output parameters
The output signal RS485 Modbus (6~24V DC) 4~20mA / Hart Two wire ( 24V DC)
Communication protocol Modbus control / HART
Resolution 1.6μA
Fault signal Constant current output; 20. 5mA
22mA
3.9mA
The integral time (0 ~ 36) s, adjustable
Blind area the ends of the antenna
The maximum distance measurement XYT 908 30 meters
XYT909 70 meters
Microwave frequency 26GHz
The measurement interval about 1 second (depending on the parameter settings)
Adjust the time about 1 second (depending on the parameter settings)
Display resolution 1 mm
Working storage and transportation
temperature (-40~70) ºC
Process temperature
(the temperature of the antenna part) (-40~100)ºC
Pressure Normal atmospheric pressure
Seismic Mechanical vibration l0m/s², (10 ~ 150) Hz
FAQ |
Normally in 1 hours, no more than 12 hours.
2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.
3. Can I get sample?
Contact with our staff online directly and they would check stock for you.
4. Can I visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China.
5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months.
7. What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, credit Assurance.