- Overview
- Recommend Products
Basic Info.
Model NO.
BC1000A0110U
Model
Bc1000A0110u
Brand
Honeywell
Name
Burner Controller
Use
Gas Burner Accessories
Environment Temperature
Normal
Customize
Yes
Deliver Time
2-15days
Term of Payment
EXW/Fob
After Warranty Service
Video Technical Support
Usage
Hydrogen, Nitrogen, Ng
Machine Size
Medium
Transport Package
Carton
Specification
25*5.5*18.5cm
Trademark
Honeywell
Origin
America
HS Code
8302600000
Production Capacity
1000
Product Description
Honeywell BC1000A0110U Controller for Industrial Combustion Burner
Action:
BC1000 is used in large commercial and industrial combustion devices flame switch. It has the following functions:1. Simple flame switch function, that is to indicate whether there is a flame.
2. Combustion safety controller, which can provide system "safe start check""Check" and flamemonitoring functions.
Brand | Honeywell |
Original | America |
Model | BC1000A0110U |
Name | Flame Switch |
Built-in safe start check circuit for simultaneous detection at start-up Whether the flame detector can work normally . If a flame is displayed at this time, it will not turn on safety relay, so the system will not get
activated when the controller start at the signal. BC1000 requires a flame ionization rod or Honeywell mini-peeper UV flame
detector to detect,measure the flame condition and output the flame signal to the controller.
PRODUCT SPECIFICATIONS
Features:
1. The structure is compact, and the way of inserting into the base is adopted easily.
2. It can be directly installed on thepanel, when there are multiple devices on the panel For easy installation, it can also be flush-mounted into a DIN slot.
2. It can be directly installed on thepanel, when there are multiple devices on the panel For easy installation, it can also be flush-mounted into a DIN slot.
3. Whenthe safe start detection is activated, abnormal flame conditions are found. condition exists, the controller will interrupt the ignition.
4. Three LED lights respectively indicate three states during operation: power Source, Flame, Safe Start Detection(SSC)
5. The intensity of the flame can be measured by the front terminal, or continuous Measurement monitoring.