Basic Info.
Model NO.
LMV37.400A2
Color
Grey
Power Supply
230V 50/60Hz
Weight
2kg
Environment Temperature
-20°c--+60ºC
Delivery Time
Payment After About 2 Days
Shipping Term
DHL/UPS/FedEx/TNT
After Warranty Service
Video Technical Support
Transport Package
Carton
Specification
25X20X 20cm
Trademark
Siemens
Origin
Germany
HS Code
8302600000
Production Capacity
1000
Product Description
Germany LMV37.400A2 Siemens OR Gas Pellet Burner Controller Control Unit For Gas Ignition Control
PRODUCT SPECIFICATIONS
Germany LMV37.400A2 Siemens OR Gas Pellet Burner Controller Control Unit For Gas Ignition Control
Brief Description:
To avoid injury to persons, damage to property or the environment, the following warning notes must be observed! LMV37.4... are safety devices! Do not open, interfere with or modify the units. Siemens does not assume responsibility for damage resulting from unauthorized interference! The chapters covering the LMV37.4... contain additional warning notes which should also be observed when using the different unit versions! After commissioning and after each service visit, check the flue gas values across the
entire output range!
entire output range!
Electrical connection of the LMV37.4...
The LMV37.4... operates with the following low-voltages:
1.SELV (Safety Extra Low-Voltage) and PELV (Protective Extra Low-Voltage)
ensure protection against electric shock hazard
2. FELV (Functional Extra Low-Voltage) without safe separation offers no protection
which, in the event of fault, would not exclude risks
1.SELV (Safety Extra Low-Voltage) and PELV (Protective Extra Low-Voltage)
ensure protection against electric shock hazard
2. FELV (Functional Extra Low-Voltage) without safe separation offers no protection
which, in the event of fault, would not exclude risks
Installation notes
1.Always run the high-voltage ignition cables separate from the unit and other cables while observing the greatest possible distances
2Ensure that the electrical wiring inside the boiler is in compliance with national and local safety regulations
3.Mains power must always be supplied via L and N. This means that no potential differential must exist between the neutral conductor N and protective earth PE
4.Phase and neutral conductor must not be interchanged (dangerous malfunctions, loss
of protection against electric shock hazard, etc.)
of protection against electric shock hazard, etc.)
Make certain that strain relief of the connected cables is in compliance with
5.the relevant standards (e.g. as per DIN EN 60730 and DIN EN 60335)
5.the relevant standards (e.g. as per DIN EN 60730 and DIN EN 60335)
6.Ensure that spliced wires cannot get into contact with
neighboring terminals. Use adequate ferrules
Run the high-voltage ignition cable completely separate from all other cables
neighboring terminals. Use adequate ferrules
Run the high-voltage ignition cable completely separate from all other cables
7.The burner manufacturer must protect unused terminals of the LMV37.4... by fitting dummy plugs (exception: X64 (reserve) and X74)
When making the wiring, the AC 120 V or AC 230 V section must be strictly separated from other voltage sections, thus ensuring protection against electric shock hazard. For more detailed information, refer to chapter Electrical connection of the LMV37.4...
8.The connectors of the connecting cables for the LMV37.4... may only be removed or exchanged when the plant is turned off (all-polar disconnection), since the BCI interface does not provide safe separation from mains voltage
9.AGV50... signal cable between LMV37.4... and AZL2... Since the BCI carries FELV (refer to chapter Electrical connection of the LMV37.4...), the connection between LMV37.4... and AZL2... must be established via the AGV50... signal cable, or by ensuring compliance with the specification. The signal cable is specified for use under the burner hood. When using other types of signal cable that do not meet the specification requirements, safety against electric shock hazard is not necessarily ensured
8.The connectors of the connecting cables for the LMV37.4... may only be removed or exchanged when the plant is turned off (all-polar disconnection), since the BCI interface does not provide safe separation from mains voltage
9.AGV50... signal cable between LMV37.4... and AZL2... Since the BCI carries FELV (refer to chapter Electrical connection of the LMV37.4...), the connection between LMV37.4... and AZL2... must be established via the AGV50... signal cable, or by ensuring compliance with the specification. The signal cable is specified for use under the burner hood. When using other types of signal cable that do not meet the specification requirements, safety against electric shock hazard is not necessarily ensured
Do not lay signal cable AGV50... from the LMV37.4... to the AZL2… together with other cables
10.Service operation with a longer signal cable from the LMV37.4...: If a longer signal cable is required for service work for example (short-time usage,
10.Service operation with a longer signal cable from the LMV37.4...: If a longer signal cable is required for service work for example (short-time usage,
PRODUCT SPECIFICATIONS
item | value |
Condition | New |
Warranty | 1.5 years |
Applicable Industries | Hotels, Garment Shops, Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Food & Beverage Factory, Farms, Restaurant, Home Use, Retail, Food Shop, Printing Shops, Construction works , Energy & Mining, Food & Beverage Shops, Other, Advertising Company |
Weight (KG) | 3 |
Showroom Location | None |
Video outgoing-inspection | Provided |
Machinery Test Report | Provided |
Place of Origin | Germany |
Brand Name | Siemens |
Type | Gas Burner |
Product name | Germany LMV37.400A2 Siemens OR Gas Pellet Burner Controller Control Unit |
Model | LMV37.400A2 |
Brand | Siemens |
After Warranty Service | Video Technical Support |
Color | Grey And White |
temperature | -20°C--+60ºC |
Mains voltage | 230 V 50...60 Hz |
Shipping Term | DHL/UPS/Fedex/TNT |
Application/Usage | Industrial Application |
Delivery | payment after about 2 days |
Germany LMV37.400A2 Siemens OR Gas Pellet Burner Controller Control Unit For Gas Ignition Control