- Overview
- Product Parameters
- Packaging & Shipping
Basic Info.
Packaging & Delivery
To be negotiated ( > 10 Pieces)
Product Description
Fluke 355 True-RMS AC/DC Clamp Meter, 2000A AC/DC
- The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
- Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
- In-rush current measurement captures 'power-on' surge current with accuracy and repeatability
- CAT IV 600 V, CAT III 1000 V rating for added user protection
- Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
- High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
- Quickly analyze readings using the MIN, MAX, and AVG functions
- Accurately measure frequency up to 1 kHz for optimum troubleshooting
- Use the display hold feature to capture readings even when the display cannot be viewed
- A large backlit display allows for easy visibility in low-lit areas
- Use the low-pass filter to smooth out noisy loads and stabilize readings
Description
Versatile and rugged tools for applications with high currents.
Confidently take reliable readings with the True-rms, Fluke 355 and 353 digital clamp meters; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.
In The Box
- 355 Clamp meter
- C43 Soft carrying case
- 6 AA batteries
- TL224 1.5 m silicone rubber test leads
- TP2 Test Probes
- AC285 Alligator Clips
- User manual
- 3 year warranty
Manuals/Guides
- Clamp Meters Application Notes
- Data sheet
- User Manual
- Statement of Memory Volatility
- Specifications
Manufacturer Specs
Electrical Specifications | ||||
Current measurement dc and ac 10 Hz to 100 Hz | Range : 40 A | Resolution | 10 mA | |
Accuracy, A | 1.5 % rdg + 15 digits | |||
Trigger Level for Inrush | 0.50 A | |||
Trigger Level for Hz Filter OFF | 2.50 A | |||
Trigger Level for Hz Filter ON | 0.50 A | |||
Range : 400 A | Resolution | 100 mA | ||
Accuracy, A | 1.5 % rdg + 5 digits | |||
Trigger Level for Inrush | 5.0 A | |||
Trigger Level for Hz Filter OFF | 2.5 A | |||
Trigger Level for Hz Filter ON | 2.5 A | |||
Range : 2000 A; 1400 ac rms | Resolution | 1 A | ||
Accuracy, A | 1.5 % rdg + 5 digits | |||
Trigger Level for Inrush | 5 A | |||
Trigger Level for Hz Filter OFF | 8 A | |||
Trigger Level for Hz Filter ON | 8 A | |||
Crest Factor (50/60 Hz) | Range : 40 A | Crest Factor* | 2 @ 33 A, 2.4 @ 27 A | |
Range : 400 A | Crest Factor* | 2 @ 330 A, 2.4 @ 270 A | ||
Range : 2000 A; 1400 ac rms | Crest Factor* | 2 @ 1000 A, 2.4 @ 833 A | ||
Current measurement ac 100.1 Hz to 1 kHz | Range : 40 A | Resolution: | 10 mA | |
Accuracy > 10 A: | 3.5 % rdg + 15 digits | |||
Trigger Level for Inrush: | 0.50 A | |||
Trigger Level for Hz Filter OFF: | 2.50 A | |||
Trigger Level for Hz Filter ON: | 0.50 A | |||
Range : 400 A | Resolution: | 100 mA | ||
Accuracy > 10 A : | 3.5 % rdg + 5 digits | |||
Trigger Level for Inrush: | 5.0 A | |||
Trigger Level for Hz Filter OFF: | 2.5 A | |||
Trigger Level for Hz Filter ON: | 2.5 A | |||
Range : 2000 A; 1400 ac rms | Resolution: | 1 A | ||
Accuracy > 10 A: | 3.5 % rdg + 5 digits | |||
Trigger Level for Inrush: | 5 A | |||
Trigger Level for Hz Filter OFF: | 8 A | |||
Trigger Level for Hz Filter ON: | 8 A | |||
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) | Range : 4 V | Resolution: | 1 mV | |
Accuracy: | 1 % rdg + 10 digits | |||
Trigger Level for Hz Filter OFF: | 0.050 V | |||
Trigger Level for Hz Filter ON: | 0.050 V | |||
Range : 40 V | Resolution: | 10 mV | ||
Accuracy: | 1 % rdg + 5 digits | |||
Trigger Level for Hz Filter OFF: | 0.25 V | |||
Trigger Level for Hz Filter ON: | 0.25 V | |||
Range : 400 V | Resolution: | 100 mV | ||
Accuracy: | 1 % rdg + 5 digits | |||
Trigger Level for Hz Filter OFF: | 6 V | |||
Trigger Level for Hz Filter ON: | 6 V | |||
Range : 600 V ac rms | Resolution: | 1 V | ||
Accuracy: | 1 % rdg + 5 digits | |||
Trigger Level for Hz Filter OFF: | 6 V | |||
Trigger Level for Hz Filter ON: | 6 V | |||
Range : 1000 V dc | Resolution: | 1 V | ||
Accuracy: | 1 % rdg + 5 digits | |||
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) | Range : 4 V | Resolution: | 1 mV | |
Accuracy: | 3 % rdg + 10 digits | |||
Trigger Level for Hz Filter OFF: | 0.050 V | |||
Trigger Level for Hz Filter ON: | 0.050 V | |||
Range: 40 V | Resolution: | 10 mV | ||
Accuracy: | 3 % rdg + 5 digits | |||
Trigger Level for Hz Filter OFF: | 0.25 V | |||
Trigger Level for Hz Filter ON: | 0.25 V | |||
Range: 400 V | Resolution: | 100 mV | ||
Accuracy: | 3 % rdg + 5 digits | |||
Trigger Level for Hz Filter OFF: | 6 V | |||
Trigger Level for Hz Filter ON: | 6 V | |||
Range: 600 V ac rms | Resolution: | 1 V | ||
Accuracy: | 3 % rdg + 5 digits | |||
Trigger Level for Hz Filter OFF: | 6 V | |||
Trigger Level for Hz Filter ON: | 6 V | |||
Ohms measurement (355 only) | Range : 400 Ω | Resolution: | 0.1 Ω | |
Accuracy: | 1.5 % + 5 digits | |||
Range: 4 kΩ | Resolution: | 1 Ω | ||
Accuracy: | 1.5 % + 5 digits | |||
Range: 40 kΩ | Resolution: | 10 Ω | ||
Accuracy: | 1.5 % + 5 digits | |||
Range: 400 kΩ | Resolution: | 100 Ω | ||
Accuracy: | 1.5 % + 5 digits | |||
Continuity beeper (355 only) | On at ≤ 30 Ω | |||
Off at ≥ 100 Ω | ||||
Frequency measurement | Measurement range | 5.0 Hz to 1 kHz | ||
Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | |||
Accuracy - 5.0 Hz to 100 Hz | 0.2 % + 2 counts | |||
Accuracy - 100.1 Hz to 1 kHz | 0.5 % + 5 counts | |||
Trigger level | Refer to current and voltage tables |
General Specifications | |
Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 |
Battery life (with typical usage, backlight off) | 100 hours |
Test leads | Rated to 1000 V |
Weight | .814 kg (1.8 lb) |
Jaw size | 58 mm (2.28 in) |
Dimensions (L x W x D) | 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
Safety rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
Environmental Specifications | ||
Operating temperature | 32 °F to + 122 °F (0 °C to +50 °C) | |
Storage temperature | -4 °F to 140 °F (-20 °C to +60 °C) | |
Operating humidity | 0 to 95 % (non-condensing) | |
Operating altitude | 2000 m | |
Storage altitude | 10,000 m | |
IP rating | 42 (indoor use only) | |
Drop test requirements | 1 m | |
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 | |
Temperature coefficients | Current: | 0.1 % of reading per °C outside 22 °C to 24 °C |
Voltage: | 0.1 % of reading per °C outside 22 °C to 24 °C |
Tech Specs
Clamp Meters/Clamp Meters Template | |
---|---|
True RMS | Yes |
Maximum Current AC | 1400 A |
Maximum Current DC | 2000 A |
Maximum Voltage AC | 1000 V |
Maximum Voltage DC | 1000 V |
Maximum Conductor Size | 2.18 IN |
Resistance | Yes |
Capacitance | No |
Auto Ranging/Manual | Auto Ranging |
In-Rush Current | Yes |
Test Equipment General Attributes | |
Unique Features | The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors. In-rush current measurement captures 'power-on' surge current with accuracy and repeatability. A large backlit display allows for easy visibility in low-lit areas. |
Warranty | 3 YEARS |
Safety Approval | CE, CSA |
IP Rating | IP42 |
Product Weight | 1.8 LBS |
Product Height | 2 IN |
Product Length | 12 IN |
Product Width | 3.75 IN |
Data Logging | No |
HTS/Schedule B Number | 9030.31.0000 |
ECCN Number | EAR99 |
Calibration Included | None |
CA Residents | Warning: Cancer and Reproductive Harm - |
Power Supply Voltage | Battery Powered |
Country of Origin | China |
Shipping Height | 4.25 IN |
Shipping Length | 14.00 IN |
Shipping Width | 8.50 IN |
As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing...