Fluke 355 True-RMS 2000 a Clamp Meter 350 Series

After-sales Service: Yes
Warranty: 1 Year Warranty
Brand: Fluke

Products Details

  • Overview
  • Product Parameters
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
Fluke 355
Customized
Customized
Certification
CE, ISO, RoHS
Display
Digital
Stucture
Electromagnetic
Voltage
1000 V
Transport Package
UPS/DHL/FedEx
Specification
300 mm x 98 mm x 52 mm
Trademark
FLUKE
Origin
USA
HS Code
9030310000
Production Capacity
50, 000 Pieces/Year

Packaging & Delivery

Package Size
50.00cm * 25.00cm * 20.00cm
Package Gross Weight
3.000kg
Lead Time
3 days (1 - 10 Pieces)
To be negotiated ( > 10 Pieces)

Product Description

Product Parameters
Fluke 355 True-RMS 2000 a Clamp Meter 350 Series

Fluke 355 True-RMS AC/DC Clamp Meter, 2000A AC/DC

  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
  • In-rush current measurement captures 'power-on' surge current with accuracy and repeatability
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the low-pass filter to smooth out noisy loads and stabilize readings
View Product Details
 

Description

Versatile and rugged tools for applications with high currents.

Confidently take reliable readings with the True-rms, Fluke 355 and 353 digital clamp meters; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

In The Box

  • 355 Clamp meter
  • C43 Soft carrying case
  • 6 AA batteries
  • TL224 1.5 m silicone rubber test leads
  • TP2 Test Probes
  • AC285 Alligator Clips
  • User manual
  • 3 year warranty

Manuals/Guides

Application Notes
  • Clamp Meters Application Notes
Other
  • Data sheet
  • User Manual
  • Statement of Memory Volatility
  • Specifications

Manufacturer Specs

Electrical Specifications
Current measurement dc and ac 10 Hz to 100 Hz Range : 40 A Resolution 10 mA
Accuracy, A 1.5 % rdg + 15 digits
Trigger Level for Inrush 0.50 A
Trigger Level for Hz Filter OFF 2.50 A
Trigger Level for Hz Filter ON 0.50 A
Range : 400 A Resolution 100 mA
Accuracy, A 1.5 % rdg + 5 digits
Trigger Level for Inrush 5.0 A
Trigger Level for Hz Filter OFF 2.5 A
Trigger Level for Hz Filter ON 2.5 A
Range : 2000 A; 1400 ac rms Resolution 1 A
Accuracy, A 1.5 % rdg + 5 digits
Trigger Level for Inrush 5 A
Trigger Level for Hz Filter OFF 8 A
Trigger Level for Hz Filter ON 8 A
Crest Factor (50/60 Hz) Range : 40 A Crest Factor* 2 @ 33 A, 2.4 @ 27 A
Range : 400 A Crest Factor* 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms Crest Factor* 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz Range : 40 A Resolution: 10 mA
Accuracy > 10 A: 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range : 400 A Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy > 10 A: 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) Range : 4 V Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range : 40 V Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range : 400 V Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rms Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dc Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) Range : 4 V Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only) Range : 400 Ω Resolution: 0.1 Ω
Accuracy: 1.5 % + 5 digits
Range: 4 kΩ Resolution: 1 Ω
Accuracy: 1.5 % + 5 digits
Range: 40 kΩ Resolution: 10 Ω
Accuracy: 1.5 % + 5 digits
Range: 400 kΩ Resolution: 100 Ω
Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only) On at ≤ 30 Ω
Off at ≥ 100 Ω
Frequency measurement Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy - 5.0 Hz to 100 Hz 0.2 % + 2 counts
Accuracy - 100.1 Hz to 1 kHz 0.5 % + 5 counts
Trigger level Refer to current and voltage tables
* Add 2 % to error spec for CF > 2
 
Back to Top
 
General Specifications
Batteries Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off) 100 hours
Test leads Rated to 1000 V
Weight .814 kg (1.8 lb)
Jaw size 58 mm (2.28 in)
Dimensions (L x W x D) 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Back to Top
 
Environmental Specifications
Operating temperature 32 °F to + 122 °F (0 °C to +50 °C)
Storage temperature -4 °F to 140 °F (-20 °C to +60 °C)
Operating humidity 0 to 95 % (non-condensing)
Operating altitude 2000 m
Storage altitude 10,000 m
IP rating 42 (indoor use only)
Drop test requirements 1 m
EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficients Current: 0.1 % of reading per °C outside 22 °C to 24 °C
Voltage: 0.1 % of reading per °C outside 22 °C to 24 °C

Tech Specs

Clamp Meters/Clamp Meters Template

True RMS Yes
Maximum Current AC 1400 A
Maximum Current DC 2000 A
Maximum Voltage AC 1000 V
Maximum Voltage DC 1000 V
Maximum Conductor Size 2.18 IN
Resistance Yes
Capacitance No
Auto Ranging/Manual Auto Ranging
In-Rush Current Yes

Test Equipment General Attributes

Unique Features The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors. In-rush current measurement captures 'power-on'
surge current with accuracy and repeatability. A large backlit display allows for easy visibility in
low-lit areas.
Warranty 3 YEARS
Safety Approval CE, CSA
IP Rating IP42
Product Weight 1.8 LBS
Product Height 2 IN
Product Length 12 IN
Product Width 3.75 IN
Data Logging No
HTS/Schedule B Number 9030.31.0000
ECCN Number EAR99
Calibration Included None
CA Residents Warning: Cancer and Reproductive Harm -
Power Supply Voltage Battery Powered
Country of Origin China
Shipping Height 4.25 IN
Shipping Length 14.00 IN
Shipping Width 8.50 IN
 
 
Packaging & Shipping
Fluke 355 True-RMS 2000 a Clamp Meter 350 Series
Fluke 355 True-RMS 2000 a Clamp Meter 350 Series
Fluke 355 True-RMS 2000 a Clamp Meter 350 Series
Fluke 355 True-RMS 2000 a Clamp Meter 350 Series
Fluke 355 True-RMS 2000 a Clamp Meter 350 Series
Fluke 355 True-RMS 2000 a Clamp Meter 350 Series

 

As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing...    

So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours