- Overview
- Product Parameters
- Packaging & Shipping
Basic Info.
Model NO.
Fluke 345
Stucture
Electromagnetic
Transport Package
UPS/DHL/FedEx
Specification
300 x 98 x 52 mm
Trademark
FLUKE
Origin
USA
HS Code
9030310000
Production Capacity
50, 000 Pieces/Year
Product Description
What's included with the Fluke 345
* Clamp Meter
* Power Log Software
* Test Leads
* Alligator Clips
* Test Probes
* USB Cable
* Carrying Case
* International AC Adapter/Battery Eliminator
* Printed English Language User Manual
* Multi-Language Manual CD
* Power Log Software
* Test Leads
* Alligator Clips
* Test Probes
* USB Cable
* Carrying Case
* International AC Adapter/Battery Eliminator
* Printed English Language User Manual
* Multi-Language Manual CD
Combines the functions of a clamp meter, oscilloscope, data logger, and digital power meter in one, making this unit ideal for measurements on switching loads such as variable frequency drives, electronic lighting, and UPS systems. Also, it's Hall Effect measurement system measures DC currents without breaking the circuit.
Fluke 345 Single-Phase Power Quality Clamp Meter
* AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
* Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance
* Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
* Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including
harmonics
* Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
* Troubleshoot harmonics: Analyze and log harmonics digitally or graphically
Fluke 345 Single-Phase Power Quality Clamp Meter
* AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
* Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance
* Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
* Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including
harmonics
* Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
* Troubleshoot harmonics: Analyze and log harmonics digitally or graphically
This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic
loads. The Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.
loads. The Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.
One of the leading wattage meters of the world, the multi-faceted Fluke 345 is packed with features such as a bright, color
display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise and a high EMC immunity design, making the Fluke 345 power analyzer ideal for troubleshooting power quality on switching loads. The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.
display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise and a high EMC immunity design, making the Fluke 345 power analyzer ideal for troubleshooting power quality on switching loads. The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.
Specification
Current Measurement | |
Measuring Range | 0 to 2000 A DC or 1400 AC RMS |
Autorange Facility | 40 A/400 A/2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 in 2000 A range |
Accuracy | |
DC and DC RMS | I > 10 A: ±1.5% rdg ±5 digits I < 10 A: ±0.2 A |
AVG | I > 10 A: ±3% rdg ±5 digits I < 10 A: ±0.5 A |
Pk | I > 10 A: ±5% rdg ±5 digits I < 10 A: ±0.5 A |
AHr | I > 10 A: ±2% rdg ±5 digits I < 10 A: ±0.5 AHr |
CF (Crest Factor) | 1.1 ≤ CF < 3: ±3% rdg ±5 digits 3 ≤ CF < 5: ±5% rdg ± 5 digits Resolution: 0.01 |
RPL (Ripple) | 2% ≤ RPL < 100%: ±3% rdg ±5 digits 100% ≤ RPL < 600%: ±5% rdg ± 5 digits Resolution: 0.01% |
Voltage Measurement | |
Measuring Range | 0 to 825 V DC or AC RMS |
Autorange Facility | 4 V/40 V/400 V/750 V |
Resolution | 1 mV in 4 V range 10 mV in 40 V range 100 mV in 400 V range 1 V in 750 V range |
DC and DC RMS | V > 1 V: ±1% rdg ±5 digits V < 1 V: ± 0.02 V |
AVG | V > 1 V: ±3% rdg ±5 digits V < 1 V: ± 0.03 V |
Pk | V > 1 V: ±5% rdg ±5 digits V < 1 V: ± 0.03 V |
CF (Crest Factor) | V > 1 V: ±5% rdg ±5 digits V < 1 V: ±5% rdg ± 5 digits Resolution: 0.01 |
RPL (Ripple) | 2% ≤ RPL < 100%: ±3% rdg ± 5 digits 100% ≤ RPL < 600%: ±5% rdg ± 5 digits Resolution: 0.1% |
Harmonics | |
THD (Total Harmonic Distortion) | 1% ≤ THD < 100%: ±3% rdg ± 5 digits 100% ≤ THD < 600%: ±5% rdg ± 5 digits Resolution: 0.1% |
DF (Distortion Factor) | 1% ≤ DF < 100%: ±3% rdg ± 5 digits Resolution: 0.1% H02 ≤ Vharm < H13: ±5% rdg ± 2 digits H13 ≤ Vharm ≤ H30: ± 10% rdg ± 2 digits |
Watts Measurement (Single - and Three-Phase) | |
Measuring Range | 0 to 1650 kW DC or 1200 kW AC |
Autoranging Facility | 4, 40, 400, 1650 kW AC |
Resolution | 1 W in 4 kW 10 W in 40 kW 100 W in 400 kW 1 kW in 1200 kW |
Accuracy | 2.5% rdg ± 5 digits W1ø <2 kW ± 0.08 kW W3ø <4 kW ± 0.25 kW |
VA Measurement (Single - and Three-Phase) | |
Measuring Range | 0 to 1650 kVA DC or 1200 kVA AC |
Autorange Facility | 4, 40, 400, 1650 kVA |
Resolution | 1 VA in 4 kVA 10 VA in 40 kVA 100 VA in 400 kVA 1 kVA in 1200 kVA |
Accuracy | VA >2 kVA: 2.5% rdg ± 5 digits VA <2 kVA: ±0.08 kVA |
VAR Measurement (Single - and Three-Phase) | |
Measuring Range | 0 to 1250 kVAR |
Autorange Facility | 4, 40, 400, 1200 kVAR |
Resolution | 1 VAR in 4 kVAR 10 VAR in 40 kVAR 100 VAR in 400 kVAR 1 kVAR in 1200 kVAR |
Accuracy | VA >4 kVAR: 2.5% rdg ± 5 digits VA <4 kVAR: ±0.25 kVAR |
Power Factor Range | 0.3 >PF <0.99 |
Power Factor (Single - and Three-Phase) | |
Measuring Range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive) |
Resolution | 0.001 |
Accuracy | ±3° |
Frequency Range | 15 Hz to 1 kHz |
Displacement Power Factor | |
Measuring Range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive) |
Resolution | 0.001 |
Accuracy | ±3° |
Frequency Range | 15 to 22 Hz and 45 to 65 Hz |
Kilowatt Hour (kWHr) | |
Measuring Range | 40,000 kWHr |
Autorange Facility | 1, 40, 400, 4000, 40,000 kWHr |
Resolution | 1 WHr in 4 kWHr 10 WHr in 40 kWHr 100 WHr in 400 kWHr 1 kWHr in 4,000 kWHr 10 kWHr in 40,000 kWHr |
Accuracy | kWHr >2 kWHr: ±3% ± 5 digits kWHr <2 kWHr: ±0.08 kWHr |
All Watts /VA /VAR /PF Measurements | Frequency range: DC and 15 Hz to 1 kHz Current range: 10 to 1400 A RMS Voltage range: 1 to 825 V RMS Maximum input: 825 V RMS/1400 A RMS Maximum overload: 1000 V RMS/10,000 A |
Frequency Measurement | |
Measuring Range | 15 Hz to 1 kHz |
Resolution | 0.1 Hz |
Accuracy | 15 to 22 Hz ± 0.5% rdg 40 to 70 Hz ± 0.5% rdg 15 to 1000 Hz ± 1% rdg |
Current Range | 10 to 1400 A RMS |
Voltage Range | 1 to 825 V RMS |
Current Measurement | |
Ranges | 10/20/40/100/200/400/1000/2000 A |
Resolution | 1 A in 40 A 10 A in 400 A 50 A in 2000 A |
Accuracy | ±3% rdg ± 1 pixel |
Maximum Overload | 10,000 A |
Voltage Measurement | |
Ranges | 4/10/20/40/100/200/400/1000 V |
Resolution | 100 mV in 4 V 1 V in 40 V 10 V in 400 V 31.25 V in 1000 V |
Accuracy | ±2% rdg ± 1 pixel |
Maximum Overload | 1000 V RMS |
Frequency Range | DC and 15 to 600 Hz |
Time Base | 2.5, 5, 10, 25, 50 ms/div |
Refresh Rate | 0.5 seconds |
Maximum Sampling Rate | 15.625 kHz |
Inrush Current Function | |
Ranges | 40, 400, and 2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 A in 2000 A range |
Accuracy | I > 10 A: ±5% rdg ± 1 pixel I < 10 A: ±0.5 A |
Maximum Overload | Maximum overload 10,000 A or RMS x frequency <400,000 |
Capture Time | 1, 3, 10, 30, 100, and 300 s |
Maximum Sampling Rate | 15.625 kHz |
Logging Memory | |
Logging Areas | Three areas that can be used individually or combined into one large area |
Averaging Periods | 1, 2, 5, 10, 30 s, 1, 5, 10, 15 min, and custom |
General Specifications | |
Display | Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight |
Power Supply | Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 |
Battery Life Typically | >10 hours (backlight on full) >12 hours (backlight reduced) |
Battery Eliminator BE345 | Input: 110/230 V, 50/60 Hz Output: 15 V DC, 300 mA |
Reference Conditions | All accuracies stated at 73.4 ± 1.8°F (23 ± 1°C) |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Temperature Coefficient of Current | ≤± 0.15% of rdg per °C |
Temperature Coefficient of Voltage | ≤± 0.15% of rdg per °C |
Maximum Relative Humidity | 80 % for temperatures up to 87°F (31°C) decreasing linearly to 50% relative humidity at 104°F (40°C) |
Maximum Operating Altitude | 6561.7' (2000 m) |
Mechanical | |
Cleaning | The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents. |
Jaw Capacity | 2.3" (58 mm) diameter |
Jaw Opening | 2.4" (60 mm) |
Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm |
Weight | 1.8 lbs (820 g) batteries included |
Electrical Safety | |
Maximum Safe Working Voltages | Current measurement: 600 V AC RMS or DC between uninsulated conductor and ground Voltage measurement: 600 V AC RMS or DC between either input terminal and ground, or 825 V between energized phase voltages (delta power config.) |
EMC | |
Emission | IEC/EN 61326-1:1997 class B |
Immunity | IEC/EN 61326-1:1997 |
As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing...
So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.