Fluke 1587FC Insulation Multimeter

After-sales Service: Yes
Warranty: 1 Year Warranty
Installation: Portable

Products Details

  • Overview
  • Product Parameters
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
Fluke 1587FC
Power Source
AC and DC
Connection Type
Test Lines
Maximum Scale
19999
Range Conversion Type
AUTO RANGZ
Additional Measuring Item
Frequency
Display
LED
Brand Name
Fluke
Model
1587FC
AC/DC Voltage Measurements Range
600 Mv 6 V 60 V 600 V 1000 V
Temperature Measurement Range
-40 to 998°f (-40 to 537°c)
Accuracy.
1%
Transport Package
UPS/DHL/FedEx
Specification
45*36*33cm
Trademark
FLUKE
Origin
China
HS Code
9030331000
Production Capacity
50, 000 Pieces/Year

Product Description

Ideal for troubleshooting and preventative maintenance, this insulation multimeter comes in a compact, handheld design, and features True RMS capabilities. Additionally, this tool is compatible with the Fluke Connect app, which allows the user to see and share measurement results wirelessly with their smartphone or tablet.

The high-performance 2-in-1 insulation digital multimeter

This insulation multimeter is the combination of a digital insulation tester that comes supplied with a full-featured, True RMS digital multimeter in a single compact, handheld unit, which enables maximum versatility for troubleshooting and preventative maintenance.

Features

  • PI/DAR timed ratio tests
  • Live circuit detection prevents insulation test if voltage >30 V is detected for added user protection
  • VFD low-pass filter for accurate motor drive measurements
  • Auto-discharge of capacitive voltage for added user protection
  • Insulation test of 0.01 MΩ to 2 GΩ
  • Insulation test voltages of 50, 100, 250, 500 V for many applications
  • AC/DC voltage, DC millivolts, AC/DC milliamps, resistance (Ω), continuity
  • Capacitance, diode test, temperature, Min/Max, frequency (Hz)
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category
  • Large display with backlight
  • Safety first. Keep yourself out of harm's way by monitoring your test measurements remotely
  • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone
  • Quickly find problems by saving and comparing measurements over time on a wireless device
Product Parameters
AC Voltage Measurements
Range 600 mV
6 V
60 V
600 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
50 to 60 Hz ±(% of Rdg + counts) ±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)
60 to 5000 Hz ±(% of Rdg + counts) ±(2% + 3)
±(2% + 3)
±(2% + 3)
±(2% + 3)1
±(2% + 3)1
Low-Pass Filter Voltage
Range 600 mV
6 V
60 V
600 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
50 to 60 Hz ±(% of Rdg + counts) ±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)
60 to 400 Hz ±(% of Rdg + counts) ±(2% + 3) - (6% - 3)
±(2% + 3) - (6% - 3)
±(2% + 3) - (6% - 3)
±(2% + 3) - (6% - 3)
±(2% + 3) - (6% - 3)
DC Voltage Measurement
Range 6 V DC
60 V DC
600 V DC
1000 V DC
Resolution 0.001 V
0.01 V
0.1 V
1 V
Accuracy ±(% of Rdg + Counts) ±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)
Input Impedance 10 MΩ (nominal), <100 pF
Nominal Mode Rejection Ratio >60 dB at 50 or 60 Hz
Common Mode Rejection Ratio >120 dB at DC, 50 or 60 Hz (1 k unbalance)
DC Millivolts Measurement
Range 600 mV DC
Resolution 0.1 mV
Accuracy ±(% of Rdg + Counts) ±(0.1 + 1)
DC and AC Current Measurement
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)1
Burden Voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)1
Burden Voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden Voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden Voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse Protection for mA Input 0.44 mA, 1000 V, IR 10 kA
AC Conversion Inputs are ac-coupled and calibrated to the RMS value of sine wave input
Ohms Measurement
Range 600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
50 MΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy +(% of Rdg+Counts)1 ±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(1.5% + 3)
Overload Protection 1000 RMS or DC
Open Circuit Test Voltage <8 V DC
Short Circuit Current <1.1 mA
Diode Test
Diode Test Indication Display voltage drop: 0.6 V at 1.0 mA nominal test current
Accuracy ±(2% + 3)
Continuity Test
Continuity Indication Continuous audible tone for test resistance below 25 Ω and off above 100 Ω
Maximum reading: 1000 Ω
Open Circuit Voltage <8.0 V
Short Circuit Current 1.0 mA typical
Overload Protection 1000 V RMS
Response Time >1 m sec
Frequency Measurement
Range 99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Resolution 0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
Accuracy ±(% of Rdg+Counts) ±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV AC V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV
DC Trigger Levels¹ to 20 kHz2: NA
6.0 V V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V
DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V
60.0 V V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V
DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V
600.0 V V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V
1000.0 V V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V
Capacitance
Range 1000 nF
10.00 µF
100.0 µF
9999 µF
Resolution 1 nF
0.01 µF
0.1 µF
1 µF
Accuracy ±(% of Rdg+Counts) ±(1.2% + 2)
±(1.2% + 2)
±(1.2% ± 90 counts)
±(1.2% ± 90 counts)
Temperature Measurement
Range -40 to 998°F (-40 to 537°C)
Resolution 0.1°F (0.1°C)
Accuracy ±(% of Rdg+Counts)1 ±(1% + 10 counts)
±(1% + 18 counts)
Insulation Specifications
Measurement Range 0.01 MΩ to 2 GΩ
Test Voltages 50, 100, 250, 500, 1000 V
Test Voltage Accuracy 20%, 0%
Short-Circuit Test Current 1 mA nominal
Auto Discharge Discharge time <0.5 second for C=1 µF or less
Live Circuit Detection Inhibit test if terminal voltage >30 V prior to initialization of test
Maximum Capacitive Load Operable with up to 1 µF load
Output Voltage
50 V (0% to +20%) Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 50.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
100 V (0% to +20%) Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 100.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
250 V (0% to +20%) Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 250 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
500 V (0% to +20%) Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 500 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 500 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 600 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 0.6 to 2.0 GΩ
Resolution: 100 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts)
   
Packaging & Shipping

 

Fluke 1587FC Insulation Multimeter
Fluke 1587FC Insulation Multimeter
Fluke 1587FC Insulation Multimeter
 
Fluke 1587FC Insulation Multimeter
Fluke 1587FC Insulation Multimeter
Fluke 1587FC Insulation Multimeter

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours