Basic Info.
Measuring Media
Liquid
Measuring Principle
Ultrasonic
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, CE
Transport Package
Standard Wooden Box
Specification
make to order
Trademark
Vacorda
Origin
China
HS Code
90261000
Production Capacity
600piece Per Month
Product Description
DN15-DN40 Universal Small Pipe Clamp-on Ultrasonic Flowmeter/ Flow Meter
Why choose us:
1. 25 years of instrumentation equipment production experience
2. Product support OEM / ODM, export to more than 100 countries
3. The company area 20,000 square meters, and 150+ orders per month
4. Provide email, skype, whatsapp provide 24-hour one-on-one technical support service online
Product Features
- Easily and friendly for installation and operation. It only takes a few minutes, from the start of installation to using the flow meter.
- Adopts a new external clamp design, which could get the flow rate without touch the measurement medium. Compared with other traditional flow meter, this could avoid pressure loss or media contamination problems.
- As the advantage of a clamp on flow meter, no need to cut off the pipe or long time stop the equipment, save the cost of time and labor costs.
- A variety of modes are available for setting and flexibility. One set is universal for all pipe size in the measuring range, and suitable for many kinds of metal and resin pipes.
- 256*128 LCD display. Display a variety of information.
- It is optional to become an ultrasonic cooling (heat) meter/ btu meter/ energy meter to realize the monitoring and measurement of energy.
Specification
Pipe material | Metal /PVC, PP or PVDF rigid plastic pipe |
Liquid type | Water/other liquid (Single liquid medium without solid particles or impurities) |
Temperature range | 0-75ºC (No freezing on the surface) |
Low velocity cut off value (Default by factory) | 0.1m/s |
Display | 256*128, LCD |
Response time | 0.5~60s |
Accuracy | ±2%, (±1% after calibration) |
Data Storage period | 300ms |
Memory for data backup | EEPROM (Data storage: over 10 years, data read/write frequency: over 1 million times) |
Power and I/O connection | M12 type aviation plug |
Output | 4-20mA |
Communication | Modbus RS485 |
(Options for output) | OCT (pulse output)/ One relay alarm (please contact the factory) |
Power supply | 10-24V VDC |
Electric power | < 3W |
Protective circuit | Power reverse connection protection, Power surge protection, |
Output short circuit protection, Output surge protection | |
Enclosure protection class | IP65 |
Environment temperature | -10 to 60°C (No freezing) |
Relative humidity | 35 to 85% RH (No condensation) |
Vibration resistance | 10 to 55 Hz |
double amplitude 1.5 mm, 2 hours in each XYZ axis | |
Impact resistant | 100 m/s2 16 ms pulse, 1000 times each for X, Y and Z axis |
Main material | Aluminum, Industrial Plastics |
cable length | 2m(standard ), PT1000 sensor standard cable length is 9m |