Basic Info.
Product Description
Place of Origin:
Hebei, China
Brand Name:
UNIT
Model Number:
UT61E
Measuring Current Range:
200μA/2200μA/22mA/220mA
Measuring Voltage Range:
220mV/2.2V/22V/220V/1000V
Measuring Resistance Range:
220Ω/2.2kΩ/22kΩ/220kΩ/
Measuring Capacitance Range:
22nF/220nF/2.2μF/22μF
Measuring Inductance Range:
2mH/20mH/200mH/2H/20H
Operating Temperature:
-40 °C ~ 1000°C
Dimensions:
200mm*93mm*40 mm
name:
Multimeter
Input Protection:
600Vrms
Auto Power Off:
Around 15 Minutes
Input Impedance for DCV:
1GΩ Max
Frequency (Hz):
10Hz-10MHz
Low Battery Indication:
≤2.5V
Power:
AA1.5*2
Standard Individual Packing:
Battery, Test Leads
Standard Accessories:
Battery, Test Leads
Product Net Weight:
370g
Packaging & Delivery
Selling Units:
Single item
Single package size:
20X10X5 cm
Single gross weight:
1.000 kg
Package Type:
box
Lead Time:
Quantity(Pieces) | 1 - 1 | >1 |
Est. Time(days) | 15 | To be negotiated |
Product Description
UT61 Series Digital Multimeters are products designed for multi-functional, high precision, high performance and automatic measurements.
UT61 Series can measure AC/DC voltage and current, resistance, diode, circuit continuity, capacitance, frequency, temperature, hFE, electromagnetic induction, etc.
UT61 Series complies with the standard IEC61010: CAT. III 1000V, CAT.IV 600V; they are widely used in Industrial Production and Service,
Technological Research and Design, College Education (Laboratory, Courses), and Automotive Industry.
Specifications | Range | Best Accuracy |
Model | UT61E | |
DC Voltage (V) | 220mV/2.2V/22V/220V/1000V | ±(0.1%+2) |
AC Voltage (V) | 220mV/2.2V/22V/220V/750V | ±(0.8%+10) |
DC Current (A) | 200μA/2200μA/22mA/220mA/2.2A/10A | ± (0.5%+10) |
AC Current (A) | 200μA/2200μA/22mA/220mA/2.2A/10A | ±(0.8%+10) |
Resistance (Ω) | 220Ω/2.2kΩ/22kΩ/220kΩ/2.2MΩ/22MΩ/220MΩ | ±(0.5%+10) |
Capacitance (F) | 22nF/220nF/2.2μF/22μF/220μF/2.2mF/22mF/220mF | ±(3.0%+5) |
Frequency (Hz) | 10Hz-220MHz | ±(0.01%+5) |
Features | ||
Display Count | 22000 | |
Auto Range | √ | |
True RMS | √ | |
Bandwidth (Hz) | 45Hz ~10kHz | |
Duty Cycle | 0.1% ~ 99.9% | √ |
Diode | √ | |
Auto Power Off | Around 15 Minutes | √ |
Continuity Buzzer | √ | |
Low Battery Indication | ≤7.5V | √ |
Data Hold | √ | |
Relative Mode | √ | |
Peak Value | √ | |
RS-232 | √ | |
Analogue Bar Graph | 46 | |
Input Protection | √ | |
Input Impedance for DCV | Around 10MΩ | √ |
Description
CTA-1000 Series CT Analyzer automatically determines all relevant current transformer values and compares the results with the selected standard. The device evaluates the current transformer as per the IEC or IEEE standard within seconds with the push of a button.
It facilitates fast and economical on-site testing and calibration of metering and protection current transformers. Manufacturers of current transformers, high voltage transformers and switchgear also use the CT Analyzer for tests during development and production.
Product Feature
1.Wide range of measurements;
2.Easy to use.One click can complete tests
3.Highest measurement accuracy: 0.05% / 2 min when calibrating on site;
4.Automatic evaluation according to IEC and IEEE standards;
5.Short commissioning times (duration of the automatic test < 2min);
6.Excellent workplace safety - Tests run at max. 180V;
7.Very small and lightweight (<9kg>
8.Professional pull box design, easy to carry, anti-vibration.
Applications
The following values can be determined using the CT/PT Analyzer:
1. CT:
(1) CT accuracy for different burdens
(2) CT ratio and phase-angle accuracy
(3) CT excitation characteristics
(4) CT inductance (saturated and unsaturated)
(5) Burden impedance
(6) CT winding resistance
(7) CT polarity
(8) ALF and FS (direct and indirect)
(9) CT residual magnetism
2. PT:
(1) PT excitation and saturation
(2) Burden impedance
(3) Winding resistance Saturated and non-saturated inductance
(4) PT polarity
Product Parameters
Type | CTA-1000C | |
Usage | CT,PT | |
Output | 0~180Vrms,12Arms,36A(peak value) | |
Voltage measurement accuracy | ±0.1% | |
CT Ratio | Range | 1~40000 |
accuracy | ±0.05% | |
PT Ratio | Range | 1~40000 |
accuracy | ±0.05% | |
Phase | Range | ±2min |
accuracy | 0.5min | |
DC resistance | Range | 0~300Ω |
accuracy | 0.2%±2mΩ | |
Burden | Range | 0~1000VA |
accuracy | 0.2%±0.02VA | |
Power supply | AC220V±10%,50Hz | |
Environmental Conditions | Operating temperature: -10ºC~50ºC | |
Weight and Dimensions | Dimensions:365mm×300mm×165mm Weight:9.5kg |
Standard Accesories:
No. | Name | Qty |
1 | Host | 1 |
2 | Up-flow reactor(optional) | 1 |
3 | Power line | 1 |
4 | Red test line | 1 |
5 | Yellow test line | 1 |
6 | Green test line | 1 |
7 | High current test line(optional) | 2 |
8 | Control line(optional) | 1 |
9 | Ground wire | 1 |
10 | Alligator clip | 4 |
11 | Alligator clip | 2 |
12 | U type insert | 4 |
13 | Thermal printing paper | 4 |
14 | U disk | 1 |
15 | Protective tube | 5 |
16 | Special screwdriver for protective tube | 1 |
17 | Quality testing report | 1 |
18 | Instruction manual | 1 |
19 | Aluminum alloy packing box | 1 |