Basic Info.
Model NO.
CD194I-1X5
Application
Electric Power
Display Ammeter Type
Single-phase Digital
Customized
Customized
Input
100V
Output
4-20mA
Export Markets
Global
Production Process
Integration
Delivery Time
Depend on Quantity
G.W
0.5kg
Manufacturers
Haiyan Jinhan Electronic Technology Co.,Ltd
Delivery
1 Week
Transport Package
Independent Carton Package
Specification
ISO9001
Trademark
jinhan
Origin
Zhejiang China
HS Code
903033900
Production Capacity
1, 000PCS/Year
Product Description
Digital Panel Meter
Feature
• Digital inputs,relay outputs and analog output can be option specified
• Modbus-RTU protocol
• User programmable,multiple parameters
• High IP
• Wide rang of operating temperature
• Varied formats of panel size
General
PM series digital display AC ammeter can be used to measure distribution system's single or three-phase current. The ammeter's transformer ratio can be programmed. It supports switch volume input, electric relay output, analog output and communication functions (Modbus-RTU Communication Protocol). There are also different installation sizes. It can replace analog pointer ammeters.
Technical Specifications:
Shape and installation size:
Order form:
1 Panel size:A2*A1
1:160*160; 2:120*120; 4:120*60; 5:96*48; 6:80*80; 7:72*72; 9:96*96; D:48*48;
2 Functional code:
I:1 Phase AC TRMS Current; I3: 3 Phase AC RMS Current;
U:1 Phase AC RMS Voltage; U3: 3 Phase AC RMS Voltage
W:1 Phase AC Active Power(Watt); W3: 3 phase Active Power(Watt)
R3: 3 phase Reactive Power(var); F:Power Frequency;
C:1 & 3 Phase Power Factor
3 Auxillary Power Supply
A:DC24V; B:AC/DC85-265V;
4 RS485
1:have; 2:no
5 Output ranges
A: 0 ... 20 mA into 0-500Ω; B:4 ... 20 mA into 0-500Ω; C:4 ...12 ... 20 mA into 0-500Ω;
D: 0 ... 5V, min 1kΩ; E:1 ... 3 ... 5V, min 1kΩ; F:1 ... 5V, min 1kΩ; (other ranges on request)
6: High & low alarm contact
1:have; 2:no
7: Voltage Input
A:57.7V; B:100V; C:220V; D:380V; (±25% Burden:0.2VA,The PT variable ratio can be set)
8: Current Input
1:1A, 5:5A; (Burden:0.3VA typically Permissible overload:2 x rated cotinuous,10 x rated - 10 secs,25 x rated - 2 secs,Frequency:50 or 60 Hz, + 2Hz,The CT variable ratio can be set)
1 Phase AC TRMS Voltage:
Panel Size | Models | RS485 | 4-20mA | alarm contact |
160*80 | PM1U | 1 | 1 | 1 |
120*120 | PM2U | 1 | 1 | 1 |
80*80 | PM6U | 1 | 1 | 1 |
120*60 | PM4U | 1 | 1 | 1 |
96*48 | PM5U | 1 | 1 | 1 |
96*96 | PM9U | 1 | 1 | 1 |
72*72 | PM7U | 1 | 1 | 1 |
48*48 | PMDU | 1 | - | - |
3 Phase AC RMS Voltage
Panel Size | Models | RS485 | 4-20mA | alarm contact |
160*80 | PM1U3 | 1 | 1 | 1 |
120*120 | PM2U3 | 1 | 1 | 1 |
80*80 | PM6U3 | 1 | 1 | 1 |
120*60 | PM4U3 | 1 | 1 | 1 |
96*48 | - | 1 | 1 | 1 |
96*96 | PM9U3 | 1 | 1 | 1 |
72*72 | PM7U3 | 1 | 1 | 1 |
48*48 | - | - | - | - |