- Overview
- Product Description
- Model List
- Company Profile
- Installation Instructions
Basic Info.
Model NO.
AZY-6830
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Function
Simple Type
Output Power
30kVA
Input Phase
3-Phase 4 Wires
Input Frequency
50Hz/60Hz
Output Phase
3-Phase 4 Wires
Input Voltage 1
380VAC ±10%
Input Voltage 2
480VAC ±10%
Input Voltage 3
680VAC ±10%
Input Voltage 4
1000VAC ±10%
Output Voltage 1
380VAC ±10%
Output Voltage 2
480VAC ±10%
Output Voltage 3
680VAC ±10%
Output Voltage 4
1000VAC ±10%
Output Frequency 1
50Hz/60Hz
Output Frequency 2
400Hz
Output Frequency 3
40-500Hz
Transport Package
Carton or Wooden Case
Specification
AZY-6830
Trademark
AZY
Origin
China
Production Capacity
1000PCS/ Month
Product Description
Frequency converter 3 phase 220v 50hz/60hz to 3 phase 115v 400hz 10kva 15kva
20kva power source
20kva power source
Model | AZY-6830 | |
Capacity | 15 kVA | |
Dimension | 800*550*1650mm | |
Weight | 360kg | |
Input | Voltage | 1 Phase 2 Wire: 220V± 10% (option *) |
Frequency | 50 Hz or 60 Hz ± 5% | |
Output | Voltage, current | 110V Setting (Low grade): 0-150V, 125A |
220V Setting 0-300V (High grade): 0-300V, 62.5A | ||
Load stabilization Rate | ≤±1% | |
Frequency | 50Hz, 60Hz up to 400Hz adjustable Note: -When the output is 400Hz, the load capacity can only reach 50% of the rated capacity. -When the output is ≤120Hz, the load capacity can reach 100% of the rated value. -You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option. | |
Frequency Stability | ≤±0.01% | |
Harmonic Distortion | Pure Sine Wave ≤2% | |
Frequency meter | 4 digit, digital frequency meter, resolution 0.1Hz/Step | |
Voltmeter | 4 digit, digital voltage meter, resolution 0.1V | |
Ammeter | 4 digit, digital ammeter, resolution 0.1A | |
Watt meter | 4 digit, digital Watt meter, resolution 0.1W | |
Protection | With overload, short circuit, over temperature | |
Instantaneous power failure protection and alarm device | ||
Working Environment | Temperature | 0 - 40 deg.ºC |
Humidity | 0 - 90% (Non condensation) |
15 kVA static pure sine wave 60Hz to 50Hz frequency converter, convert single phase AC power 120V 60 Hz to 240V 50 Hz by built-in step up power transformer, make international 50Hz/60Hz power system compatible easily.
SPECIFICATION (IPS-FC61) SINGLE-PHASE INPUT SINGLE-PHASE OUTPUT
Model (IPS-FC61) | 61005 | 6101 | 6102 | 6103 | 6105 | 6106 | 6110 | 6115 | ||
Output capacity (KVA) | 0.5 | 1 | 2 | 3 | 5 | 6 | 10 | 15 | ||
Rated power output(KW) | 0.4 | 0.8 | 1.6 | 2.4 | 4 | 4.8 | 8 | 12 | ||
Circuit mode | IGBT/SPWM | |||||||||
AC input | Single-phase 220V/50Hz or 60Hz | |||||||||
AC output | Output Phase | Single-phase 220V | ||||||||
Voltage | Low range | 0~150V Adjustable | ||||||||
High range | 0~300V adjustable | |||||||||
Frequency | 40~499.9HZ can be setting by software | |||||||||
Max current | low-grade | 4.2A | 8.4 A | 17 A | 25 A | 42 A | 50 A | 84 A | 125 A | |
high-grade | 2.1 A | 4.2 A | 8.4 A | 12.5 | 21 A | 25 A | 42 A | 63 A | ||
Frequency stability rate | Frequency stability rate | |||||||||
Load voltage stabilizing rate | Load voltage stabilizing rate | |||||||||
Waveform distortion degree | Waveform distortion degree | |||||||||
Response time | Response time | |||||||||
Indication resolution | Digit frequency | 4 digits display, resolution 0.1Hz | ||||||||
Digit voltage | 4 digits virtual value display, resolution 0.1V | |||||||||
Digit current | 4 digits virtual value display, resolution 0.01A | |||||||||
Digit power | 4 digits virtual value display, resolution 1W | |||||||||
Protection | overvoltage, over current, overload, over temperature and short-circuit, as well as automatic jump protection and alarm device | |||||||||
Cooling | Forced fan cooling | |||||||||
Working temperature | 0ºC~45ºC, | |||||||||
Environment humidity | Relative 0~90%( non-coagulation state ) | |||||||||
Product Dimension(cm) | 43*18*44 | 43*18*47 | 43*65*52 | 55*74*52 | ||||||
Net weight (kg) | 26 | 32 | 37 | 48 | 63 | 80 | 145 | 175 |
SPECIFICATION (IPS-FC62) SINGLE-PHASE INPUT TRI-PHASE OUTPUT
Model (IPS-FC62) | 6220 | 6230 | 6245 | 6260 | 62100 | 62120 | 621150 | 62200 | ||
Output capacity (KVA) | 20 | 30 | 45 | 60 | 100 | 120 | 150 | 200 | ||
Rated power output(KW) | 16 | 24 | 36 | 48 | 80 | 96 | 120 | 160 | ||
Circuit mode | IGBT/SPWM | |||||||||
AC input | Tri-phase 220V/50Hz or 60Hz | |||||||||
AC output | Output Phase | 3-phases 380V | ||||||||
Voltage | Low range | 0~150V Adjustable | ||||||||
High range | 0~300V adjustable | |||||||||
Frequency | 40~499.9HZ can be setting by software | |||||||||
Max current | low-grade | 168A | 250 A | 375 A | 500 A | 834 A | 1000 A | 1250 A | 1667 A | |
high-grade | 84 A | 125 A | 188 A | 250 A | 417 A | 500 A | 625 A | 834 A | ||
Frequency stability rate | Frequency stability rate | |||||||||
Load voltage stabilizing rate | Load voltage stabilizing rate | |||||||||
Waveform distortion degree | Waveform distortion degree | |||||||||
Response time | Response time | |||||||||
Indication resolution | Digit frequency | 4 digits display, resolution 0.1Hz | ||||||||
Digit voltage | 4 digits virtual value display, resolution 0.1V | |||||||||
Digit current | 4 digits virtual value display, resolution 0.01A | |||||||||
Digit power | 4 digits virtual value display, resolution 1W | |||||||||
Protection | overvoltage, over current, overload, over temperature and short-circuit, as well as automatic jump protection and alarm device | |||||||||
Cooling | Forced fan cooling | |||||||||
Working temperature | 0ºC~45ºC, | |||||||||
Environment humidity | Relative 0~90%( non-coagulation state ) | |||||||||
Product Dimension(cm) | 58*74*52 | 70*120*110 | 80*120*150 | 100*150*160 | ||||||
Net weight (kg) | 285 | 385 | 420 | 560 | 960 | 1150 | 1450 | 1900 |
Model IPS-FC63 | 6303 | 6306 | 6310 | 6315 | 6320 | 6330 | 6345 | 6360 | 63100 | 63120 | 63400 | 63500 | 63600 |
Rated Capacity (KVA) | 3 | 6 | 10 | 15 | 20 | 30 | 45 | 60 | 100 | 120 | 400 | 500 | 600 |
Phase Capacity (KVA) | 1 | 2 | 3.3 | 5 | 7 | 10 | 15 | 20 | 33 | 40 | 134 | 167 | 200 |
AC Input | Single phase 220V/50Hz,60Hz | Tri phase 380V/50Hz,60Hz | |||||||||||
AC Output | |||||||||||||
Phase | Trip phase (phase difference 120°±2°) | ||||||||||||
Output Frequency | 40~499.9HZ can be setting by software | ||||||||||||
AC Voltage Output | |||||||||||||
Low Range | Phase voltage:0V~150V (line voltage:0V~260V) | ||||||||||||
High Range | Phase voltage:0V~300V (line voltage:0V~520V) | ||||||||||||
Max Current output | |||||||||||||
0~150V | 8.4A | 16.8A | 28A | 42A | 50A | 84A | 125A | 168A | 276A | 336A | 1112A | 1400A | 1667A |
0~300V | 4.2A | 8.4A | 14A | 21A | 25A | 42A | 63A | 84A | 138A | 168A | 556A | 700A | 833A |
Frequency Stability Rate | ≤±0. 1% | ||||||||||||
Load Stability Rate | ±0.5% | ||||||||||||
Waveform Distortion | ≤±2%(resistance load) | ||||||||||||
Response Time | ≤2ms | ||||||||||||
Indication Resolution | |||||||||||||
Digit Frequency | 4 digit resolution 0.1Hz | A,B,C phase can change optionally | |||||||||||
Digit Voltage | 4 digit resolution 0.1V | ||||||||||||
Digit Current | 4 digit resolution: below 4A:0.001A; above 4A:0.01A | ||||||||||||
Digit Power | 4 digit resolution 1W | ||||||||||||
Protection | Input no fuse switch, output fuse switch, electronics circuit speed detect the over voltage, over current, over load, over temperature, short circuit and automatic jump protection and alarm. | ||||||||||||
Cooling | Forced fan cooling | ||||||||||||
Environment | |||||||||||||
Operation Temperature | 0ºC~45ºC | ||||||||||||
Relative Humility | 0~90%(non condensing ) | ||||||||||||
Working Temperature | 0ºC~45ºC, Relative 0~90%( non-coagulation state ) | ||||||||||||
Shape | |||||||||||||
Dimensions (MM) | 190* 305* 430 | 280* 450* 500 | 620* 320* 620 | 950* 560* 650 | 700* 1340* 1280 | 1700* 1750* 1000 | 1650* 850* 1090 | 1650* 800* 1200 | |||||
Weight(Kg) | 30 | 35 | 45 | 60 | 78 | 140 | 170 | 280 | 650 | 1050 | 1250 | 1350 | 1450 |
SPECIFICATION (IPS-FC68) 3-PHASES INPUT 3-PHASES OUTPUT
Model | 68005 | 6801 | 6802 | 6803 | 6805 | 6810 | 6815 | 6820 | 6830 | 6845 | 6860 | 68100 | |
Rated Capacity (KVA) | 500 | 1 | 2 | 3 | 5 | 10 | 15 | 20 | 30 | 45 | 60 | 100 | |
Circuit Mode | IGBT/PWM | ||||||||||||
AC Input | Single-phase 220V/50Hz,60Hz | Tri-phase 380V/50Hz,60Hz | |||||||||||
AC Output | |||||||||||||
AC Output | Phase | Single phase | |||||||||||
Voltage | Low Range | 0V~150V | |||||||||||
Low Range | 0V~300V | ||||||||||||
Frequency | 40~499.9HZ can be setting by software | ||||||||||||
Max Current | 0V-150V | 4.2A | 8.4A | 16.8A | 25A | 42A | 84A | 126A | 168A | 250A | 375A | 500A | 834A |
0V-300V | 2.1A | 4.2A | 8.4A | 12.5A | 21A | 42A | 63A | 84A | 125A | 188A | 250A | 417A | |
Frequency Stability Rate | ≤±0.1% | ||||||||||||
Load Stability Rate | ±0.5% | ||||||||||||
Waveform Distortion | ≤2%(linear load) | ||||||||||||
Respond Time | Max 2ms | ||||||||||||
Indication Resolution | |||||||||||||
Digit Frequency | 4 digit resolution 0.1Hz | ||||||||||||
Digit Voltage | 4 digit resolution 0.1V | ||||||||||||
Digit Current | 4 digit resolution below 4A:0.001A above 4A:0.01A | ||||||||||||
Digit Power | 4 digit resolution below 200W:0.1W above 200W:1W | ||||||||||||
Digit Frequency | 4 digit resolution 0.001 | ||||||||||||
Protector | Input no fuse switch, output fuse switch, electronics circuit speed detect the over voltage, over current, over load, over temperature, short circuit and automatic jump protection and alarm. | ||||||||||||
Cooling | Forced fan cooling | ||||||||||||
Environment | |||||||||||||
Operate Temperature | 0ºC~45ºC | ||||||||||||
Related Humility | 0~90%(non condensing ) | ||||||||||||
Dimension H*W*D(mm) | 187*428*440 | 650*430*520 | 900*450*710 | 900*560*710 | 1200*560*800 | 1200*850*1020 | 1600*800*1200 |
COMMON SPECIFICATIONS
Phase number | Single-phase | Three-phase | |
Capacity | 500VA-45KVA | 3KVA-400KVA | |
Production method | IGBT / PWM pulse width modulation mode | ||
Input | Voltage (optional) | 1-Phase 2-wire + G:110V(2-5KVA) , 200V/230V/240Z±10% | |
Output | 3-phase 4-wire + G:Y connection 190/110,200/115.208/120,220/128,230/132,240/139V±10% | ||
3-phase 4-wire + G: Y connection:380/220,400/230,415/240,400/254,460/265.480/277V±10% | |||
3-phase 3-wire + G: delta connection:220,230,240,380,400,415,440V±10% | |||
Frequency (optional) | 40~499.9HZ can be setting by software | ||
Voltage | 110V system:0-150V(Low Range) | Options: 1. 0-600v; 2. Standard setting voltage: ± 10% ~ + 25%, - 10% -- 30% preset | |
220V system:0-300V(High Range) | |||
Load stability rate | ≤±1% | ||
Frequency | Frequency 40.0hz to 1990.9hz (programmable) | ||
Frequency stability | ≤±0.01% | ||
Harmonic distortion | Sine wave, ≤2% | ||
Frequency table | 4-digit, digital frequency meter, resolution 0.1hz/step | ||
Voltmeter | 4-digit, digital voltmeter, resolution 0.1V | ||
Ammeter | 4-digit, digital ammeter, resolution 0.1A | ||
Wattmeter | 4-digit, digital wattmeter, resolution 0.1W | ||
Protector | It has overload, over high temperature, short circuit, instantaneous power-off protection and alarm device | ||
Temperature | Temperature: 0-40deg. ºC | ||
Work environment | 0.90% (noncondensing state) |
APPLICATION
1 | Home appliances | 8 | Photovoltaic |
2 | Motors | 9 | Lamps |
3 | Power tools | 10 | Electronic transformers |
4 | Switching power supplies | 11 | Electronic components |
5 | Power adapters | 12 | Low-voltage distribution |
6 | UPS | 13 | Power |
7 | Information and communication | 14 | Other industries |
Frequency Converter Price List-IDEALPLUSING | ||||
AZY-FC61 Series-Single Phase Input, Single Phase Output | ||||
NO | Capacity | Model | Input voltage and frequency | Output voltage and frequency |
3 | 2KVA | AZY-FC6102 | Single phase 2 wires 220VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
4 | 3KVA | AZY-FC6103 | Single phase 2 wires 220VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
5 | 5KVA | AZY-FC6105 | Single phase 2 wires 220VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
6 | 10KVA | AZY-FC6110 | Single phase 2 wires 220VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
7 | 15KVA | AZY-FC6115 | Single phase 2 wires 220VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
AZY-FC62 Series-Three Phases Input, Single Phase Output | ||||
NO | Capacity | Model | Input voltage and frequency | Output voltage and frequency |
10 | 10KVA | AZY-FC6210 | 3 phases 4 wires 380VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
11 | 15KVA | AZY-FC6215 | 3 phases 4 wires 380VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
12 | 20KVA | AZY-FC6220 | 3 phases 4 wires 380VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
13 | 30KVA | AZY-FC6230 | 3 phases 4 wires 380VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
14 | 40KVA | AZY-FC6240 | 3 phases 4 wires 380VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
15 | 45KVA | AZY-FC6245 | 3 phases 4 wires 380VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
16 | 50KVA | AZY-FC6250 | 3 phases 4 wires 380VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
17 | 60KVA | AZY-FC6260 | 3 phases 4 wires 380VAC±15% 50/60Hz | Single phase 2 wires, 0-300V 40.00-499.9Hz |
AZY-FC63 Series-Single Phase Input, Three Phases Output | ||||
NO | Capacity | Model | Input voltage and frequency | Output voltage and frequency |
20 | 6KVA | AZY-FC6306 | Single phase 2 wires 220VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
21 | 10KVA | AZY-FC6310 | Single phase 2 wires 220VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
22 | 15KVA | AZY-FC6315 | Single phase 2 wires 220VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
23 | 20KVA | AZY-FC6320 | Single phase 2 wires 220VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
24 | 30KVA | AZY-FC6330 | Single phase 2 wires 220VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
AZY-FC68-Series-Three Phases, Three Phases Output | ||||
NO | Capacity | Model | Input voltage and frequency | Output voltage and frequency |
27 | 10KVA | AZY-FC6810 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
28 | 15KVA | AZY-FC6815 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
29 | 20KVA | AZY-FC6820 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
30 | 30KVA | AZY-FC6830 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
31 | 45KVA | AZY-FC6845 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
32 | 60KVA | AZY-FC6860 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
33 | 75KVA | AZY-FC6875 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
34 | 90KVA | AZY-FC6890 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
35 | 100KVA | AZY-FC68100 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
36 | 150KVA | AZY-FC68150 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
37 | 200KVA | AZY-FC68200 | 3 phases 4 wires 380VAC±15% 50/60Hz | 3 phases 4 wires, 0-520V 40.00-499.9Hz |
The professional technical R&D personnel of Shenzhen Anziya Technology Co., Ltd. have an average of more than ten years of rich experience in the industry. The production workshop facilities are fully equipped with integrated production lines and integrated production control. From the production of raw materials to the delivery of products, strict quality inspections are carried out. , prevent substandard products from leaving the factory, and strive to ensure that every customer receives a satisfactory product.
Shenzhen Anziya Technology Co., Ltd. has achieved the rapid development of itself and many customers with high-quality products and services. We will use a humble and rigorous mentality, the concept of honesty and trustworthiness, reasonable prices, respecting promises and abiding by contracts, and ensuring product quality. Quality wins the trust of our customers.
The frequency (50 Hz or 60 Hz) of AC power source was selected arbitrarily when systems were stand-alone (not interconnected) Therefore if you had a water mill driving a generator to power the machines in your factory it didn't really matter. This gave rise to a wide range of frequencies being used from around 15 Hz up to 90 Hz and beyond. This was OK for powering machinery. However when electric light was introduced it was clear that at any frequency below about 45 Hz you could see an incandescent light bulb flickering. Thereafter 50Hz was the general minimum. AEG in Germany drove towards 50Hz which spread throughout Europe and Westinghouse settled on 60Hz which became the norm in the US. These practices spread across the world according to areas of influence - Africa and most of Asia is 50Hz while all of the Americas, parts of Japan and the Philippines and the Pacific islands are all 60Hz. This leads to some interesting situations with US bases in Europe which have to have 60Hz generators and are generally isolated from the normal supplies. You can use a static frequency converter to change between them.